Viessmann · Boiler troubleshooting
Check mixing valve motor rotation direction
What is going on
After power-up the boiler runs a self-test that opens and closes the mixing valve. Then the valve is set manually to Open to confirm the flow temperature rises.
Likely causes
- Motor turning in the wrong direction
- Mixing valve set incorrectly fitted
Check in this order
- Switch the boiler on and let the self-test run.
- Set the mixing valve manually to Open.
- Check that the flow temperature sensor reads a higher temperature.
- If the temperature drops, reverse the motor or refit the mixing valve set.
Applies to: Vitodens 200-W B2HA extension kit
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitodens 200-W B2HA service instructions, p. 86. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.