Check condensate drain and trap
What is going on
Keeps condensate draining freely to avoid a burner shutdown.
Likely causes
- Condensate not draining freely, which builds up in the bottom of the boiler and causes a fault message
Check in this order
- Remove retaining clip A from condensate trap B.
- Disconnect flexible discharge tubing C from the trap.
- Remove the condensate trap from the boiler.
- Clean out debris and refill the trap with water.
- Reinstall the trap and secure it with the clip.
- Reconnect the flexible discharge tubing.
- Do not connect other drains, such as a water softener backwash pipe, to the condensate drain.
Applies to: Vitodens 200-W B2HA 19, 28, 35
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Viessmann Vitodens 200-W B2HA service instructions, p. 23. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.