Changing heating times F1 and F2 on Lago FB
What is going on
Set the heating periods for each heating program on the remote.
Check in this order
- Set the mode dial to Mo-Fr. The first hour block flashes and shows 0:00.
- Turn the value dial left until the display shows the start time of the first heating period.
- Turn the value dial right until the display shows the end time of the first heating period.
- Turn the value dial left until the display shows the start time of the second heating period.
- Turn the value dial right until the display shows the end time of the second heating period.
- Note programming cycles around; after 23:45 the hour block returns to 0:00.
Applies to: Lago FB remote control, heating programs F1 and F2
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Versatronik 200 installation and operating manual, p. 58. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.