Change reduced room temperature (night)
What is going on
Sets the night-time room temperature. A value of 3°C / 37°F makes the display show freeze-up protection.
Check in this order
- Open the hinged cover on the programming unit.
- Press the heating circuit selector button; it lights.
- Press the reduced room temperature button; the current value flashes.
- Use the up or down button until the required value shows.
- Press confirm; the value stops flashing and is stored.
- Close the hinged cover.
Applies to: Vitotronic 300 GW2
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitotronic 300 GW2 operating instructions, p. 8. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.