Viessmann · Boiler troubleshooting

Change or scan the space heating time program

Vitotronic 200-H

What is going on

Set the on and off times for space heating phases. Scanning shows the preset phases without changing them.

Check in this order

  1. Open the hinged cover on the programming unit.
  2. Press the heating time program button (ur); the display changes to 'Exit? Yes' when you are in setting mode.
  3. Use the day selector to choose '1-7' for identical phases every day, or a single weekday (Mo, Tu, etc.) for different phases.
  4. Confirm, then set each phase's ON and OFF times with the up/down buttons and confirm each one.
  5. To exit at any time, press ur and confirm 'Exit? Yes'.
  6. Close the hinged cover.

Applies to: Vitotronic 200-H HK1S/HK3S, space heating time program

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitotronic 200-H operating instructions, p. 16. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.