Viessmann · Boiler troubleshooting

Change or delete a DHW time phase

Vitodens 100-W B1HEVitodens 100-W B1KE

What is going on

Edit changes the start or end time of an existing phase. Delete removes a phase entirely. On the B1KE, deleting all time phases switches off the DHW comfort function.

Check in this order

  1. Open DHW, then Time programs, then DHW, then the day of the week.
  2. Select the time phase.
  3. To change it, choose Edit, adjust times and confirm each entry.
  4. To remove it, choose Delete and confirm.
  5. Acknowledge the message and hold Back for about 4 seconds to exit.

Applies to: Vitodens 100-W B1HE and B1KE, DHW time program

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 100-W B1HE/B1KE operating instructions, p. 13, 15. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.