Viessmann · Boiler troubleshooting
Brief scan line contents
What is going on
Each brief scan line shows system details. Fields 1 to 6 are read left to right.
Check in this order
- Line 1 system type 01 to 10; software version control unit; software version programming unit.
- Line 2 appliance version; device identification ZE-ID.
- Line 3 number of KM BUS participants; software version solar control module SM1.
- Line 4 burner control unit software version, type and version.
- Line 5 internal calibration details; software version extension AM1 and EA1.
- Line 6 flow rate sensor switching state; flow rate too low or not present (field 1).
- Line 7 LON subnet address/system number; LON node address.
- Line 8 LON SBVT configuration; LON software version; communication co-processor; LON Neuron chip version; number of LON participants.
Applies to: Vitodens 200-W B2HB 45, 57, 160, 199
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitodens 200-W B2HB service manual, p. 72. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.