Boiler short-cycling or inadequate DHW supply
What is going on
Likely caused by DHW piping that is too small or by a DHW coil whose pressure drop is too high for the boiler pump head.
Likely causes
- DHW supply or return piping between boiler and tank is smaller than the minimum stated in the manual.
- Non-Viessmann DHW tank coil pressure drop is higher than the boiler pump head can overcome.
Check in this order
- Check DHW supply and return pipe size against the minimum on page 21 (the size is garbled in this extract; confirm it in the full manual).
- For non-Viessmann tanks, calculate DHW coil pressure drop against boiler pump head.
- Correct piping or tank selection so the boiler heat exchanger gets sufficient flow.
Applies to: Vitodens 100-W B1HE with DHW storage tank, B1KE
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitodens 100-W B1HE/B1KE technical data manual, p. 21 and p. 22. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.