Assembling the cast iron sections

Vitorond 200 VD2A

What is going on

Disassembly and reassembly steps for boilers shipped in individual sections. Skip the disassembly steps if the boiler arrives assembled.

Check in this order

  1. Unscrew the four bolts and remove the boiler door from its hinges.
  2. Remove the installation accessories from the combustion chamber.
  3. Remove turbulators from the secondary flue passes (models 125 to 195 only).
  4. Remove the M12 nuts and distribution tube cover, along with the studs.
  5. Remove the distribution tube from the boiler.
  6. Loosen and remove the tie rods.
  7. Remove the rear section and the studs from the boiler return port.
  8. Assemble the sections with silicone sealant, keeping all hardware. Accessories are in the accessory pack inside the combustion chamber and the 'Installation Fittings' carton.

Applies to: Vitorond 200 VD2A

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitorond 200 VD2A installation instructions, p. 16. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.