Application Example 5 system layout
What is going on
One direct-connected boiler circuit without a mixing valve, plus two mixing-valve heating circuits, with a DHW tank. The Vitotronic 300 runs the boiler, the DHW tank and both mixing circuits through the Power Pump Module and the KM-BUS expansion module. A supply check valve is needed only where the boiler return is piped as one common connection.
Check in this order
- Fit the Vitotronic 300 with the Power Pump Module and the KM-BUS expansion module.
- Connect mixing valve 1 and mixing valve 2 through their actuator accessory kits, with the supply sensor in each kit.
- Wire the DHW tank sensor and the DHW pumps to their connections.
- Fit a supply check valve only if the boiler return is one common connection.
- Connect the return water sensor only where the design needs it, for example underfloor heating that controls supply and return temperature.
Applies to: Application Example 5, Vitotronic 300 with two mixing-valve circuits
More boiler guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitotronic 300 installation instructions, p. 8. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.