Viessmann · Boiler troubleshooting

Access the control unit connections

Vitodens 222-F, B2TB

What is going on

Opening the external accessory connection box and the control console to reach the terminals.

Check in this order

  1. Remove both screws from the external accessory connection box front plate and set them aside.
  2. Remove both retaining screws and set them aside.
  3. Pull the external accessory connection box forward and swing it down.
  4. Tilt the bottom of the box cover forward, lift it off the locating pins, and set it aside.
  5. Slide both sides of the programming unit cover closed.
  6. Release the hinged hooks on both sides of the control console.
  7. Lift the cover and fold the control console down.
  8. Release the locking tabs and remove the cover to reach the control base.

Applies to: Vitodens 222-F, B2TB 19, 35, 68, 125

More boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitodens 222-F, B2TB installation instructions, p. 17-19. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.