Viessmann · Boiler
F.14 Outside temperature sensor short circuit
What the control is telling you
Control behaves as if outside temperature were 0 C (32 F).
Applies to: Vitodens 200-W B2HE 85, 120, 150, 199
Likely causes
- Shorted outside sensor or wiring
Test and repair steps
- Check the outside sensor and its connection (external plug, contacts 1 and 2).
- Replace the faulty part.
Models that show this code
4 models in Vitodens 200-W B2HE
Other codes on the same units
- F.104 External fault message input active
- F.11 Solar collector sensor open circuit
- F.12 Solar collector sensor short circuit
- F.13 Outside temperature sensor open circuit
- F.142 CAN bus communication error
- F.143 Fan overheating (air mass flow sensor / recirculation)
- F.15 Storage tank sensor open circuit (solar/backup)
- F.16 Storage tank sensor short circuit (solar/backup)
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Viessmann Vitodens 200-W B2HE 85/120/150/199 Service Instructions 6167 813-24 (09/2026), Fault messages, p.62-73. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.