Skytech · Gas fireplace
4 Beeps Every Second Sensor safety - flame sensed before ignition
What the control is telling you
The pilot flame sensor sees a flame when an ignition sequence starts, or the sensor is shorted to ground.
Applies to: Skytech AF-4000 MOD-1, AF-4000 MOD A and SMART MOD remote modules (used on many fireplace brands)
Likely causes
- Pilot flame actually present with the valve off (valve not closing)
- Flame sensor shorted to ground
- Failed pilot assembly or module
Test and repair steps
- Clear it press OFF, then ON to retry a normal ignition.
- Check whether a pilot flame is still there with the valve turned OFF; if yes, the valve must be replaced.
- Check the flame sensor and its lead for a short to ground.
- Replace the pilot assembly, then the module if the fault stays.
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Skytech Audible Alerts & Error Codes for AF-4000 MOD-1 / MOD A / SMART MOD, p.2-3. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.