Skytech · Gas fireplace
4 Beeps Every 2 Seconds Thermal safety - module overheated
What the control is telling you
The module's internal temperature went above 170°F.
Applies to: Skytech AF-4000 MOD-1, AF-4000 MOD A and SMART MOD remote modules (used on many fireplace brands)
Likely causes
- Module mounted in an unapproved, too-hot location (too close to the burner)
Test and repair steps
- Let the module cool below 160°F, then press ON.
- Check where the module is mounted; if it is too close to the burner or in an unapproved spot, move it somewhere cooler.
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Skytech Audible Alerts & Error Codes for AF-4000 MOD-1 / MOD A / SMART MOD, p.2-3. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.