Rinnai · Tankless water heater
21 PC board data transfer error
What the control is telling you
Data/parameter transfer to a PC board (typically a replacement board) did not complete correctly.
Applies to: SENSEI Series; SENSEI RX/CX Series
Likely causes
- Data transfer incomplete after PC board replacement
- Parameters not programmed correctly for the model
- Board replacement/data transfer instructions not followed
- Gas valve parameters missing or wrong (SENSEI RX/CX)
Test and repair steps
- If the PC board was replaced, confirm the data transfer process finished.
- Confirm all parameters match the water heater model installed.
- Confirm the data transfer instructions were followed during board installation.
- SENSEI If transfer failed, manually program all 14 parameters per the PC Board Replacement Instructions shipped with the new board.
- SENSEI RX/CX If transfer failed, enter the gas valve parameters correctly per the Gas Valve Replacement Instructions (100000855) or PCB Replacement Instructions (100000854).
Settings for these units
- RSC supply connection sizes · SENSEI
- RSC water quality limits · SENSEI
- RSC clearances to combustibles · SENSEI
- RSC temperature settings available · SENSEI
- RX supply connection sizes · SENSEI RX/CX
- RX water quality limits · SENSEI RX/CX
- RX water treatment and flushing by hardness · SENSEI RX/CX
- RX clearances to combustibles · SENSEI RX/CX
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Rinnai Troubleshooting TWH Diagnostic Codes (100000652), p.32. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.