Majestic · Gas fireplace

3 RED No sensor signal

High severity DVBL7 Signature Command

What the control is telling you

Three red flashes: the control does not see a flame signal from the pilot sensor.

Applies to: 300DVBLN/PSC7, 400DVBLN/PSC7, 500DVBLN/PSC7 (Signature Command)

Likely causes

  • Pilot sensor not sitting in the pilot flame (flame too small)
  • Pilot connections loose

Test and repair steps

  1. Check the pilot connections at the control board
  2. Adjust the sensor position in the flame or replace the pilot assembly

Other codes on the same units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Majestic DVBL7 Series Installation and Operating Instructions, p. 41, p. 48. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.