Lennox · Furnace
E Error recall mode (button menu)
What the display is showing
A solid E in the button menu. Release the button to scroll the last 10 stored errors.
Applies to: EL296UHV(X) with control 103130-XX or 107045-XX
What to do
- Hold the button until E shows, then release.
- Read the stored codes (newest first).
- To clear them, choose c in this menu and press the button again while the c flashes.
- Exit by holding the button until three bars show.
Settings for these units
Recommended filter size by cabinet width · EL296UHV
| Cabinet width | Side return | Bottom return |
|---|---|---|
| 17-1/2 in. | 16 x 25 x 1 in. (1) | 16 x 25 x 1 in. (1) |
| 21 in. | 16 x 25 x 1 in. (1) | 20 x 25 x 1 in. (1) |
| 24-1/2 in. | 16 x 25 x 1 in. (2) | 24 x 25 x 1 in. (1) |
Number in brackets is the quantity of filters.
Filters are field supplied and installed outside the furnace; inspect monthly.
Recommended filter size by cabinet width · Lennox SL280UHV
| Cabinet width | Side return | Bottom return |
|---|---|---|
| 14-1/2 in. | 16 x 25 x 1 in. (1) | 14 x 25 x 1 in. (1) |
| 17-1/2 in. | 16 x 25 x 1 in. (1) | 16 x 25 x 1 in. (1) |
| 21 in. | 16 x 25 x 1 in. (1) | 20 x 25 x 1 in. (1) |
| 24-1/2 in. | 16 x 25 x 1 in. (2) | 24 x 25 x 1 in. (1) |
Number in brackets is filter quantity; filters are field supplied.
Never run the unit without a filter installed.
- Filter sizes by cabinet width · Lennox ML180UHE
- Filter sizes by cabinet width · Lennox SL297NV
Models that show this code
34 models in EL296UHV, Lennox SL280UHV, Lennox SL280UHNV, Lennox SL297NV, Lennox ML180UHE
Other codes on the same units
- . Idle - no call
- = Two bars - soft disable
- A Blower airflow setting
- F Flame signal mode (button menu)
- LGWP Test button Low GWP refrigerant detection board: modes and Test button
- P Program unit size (button menu)
- Power-up size code Unit size code shown at power-up (variable speed)
- U Discharge air temperature
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Lennox EL296UHV(X) Unit Information, Corp 1125-L5 (rev. 03/2022), Tables 4-5 (diagnostic modes and LED codes), printed p.32-33. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.