Lennox · Furnace

c Clear stored errors (inside error recall)

Menu / mode display EL296UHVLennox SL280UHVLennox SL280UHNVLennox SL297NVLennox ML180UHE

What the display is showing

A lowercase c in the error recall menu is the option to erase all stored error codes. Press the button a second time while the c is flashing to confirm; otherwise nothing is erased.

Applies to: Lennox EL296UHV, SL280UHV/SL280UHNV, SL297UHNV and ML180UHEK furnaces with 7-segment integrated control

What to do

  1. Enter error recall by holding the button until E shows, then release.
  2. Scroll the recall menu until c shows (it changes about every 5 seconds).
  3. Press the button again while c is still flashing to delete all stored codes.
  4. Exit by holding the button until three bars show.

Settings for these units

Recommended filter size by cabinet width · EL296UHV

Cabinet widthSide returnBottom return
17-1/2 in.16 x 25 x 1 in. (1)16 x 25 x 1 in. (1)
21 in.16 x 25 x 1 in. (1)20 x 25 x 1 in. (1)
24-1/2 in.16 x 25 x 1 in. (2)24 x 25 x 1 in. (1)

Number in brackets is the quantity of filters.

Filters are field supplied and installed outside the furnace; inspect monthly.

Recommended filter size by cabinet width · Lennox SL280UHV

Cabinet widthSide returnBottom return
14-1/2 in.16 x 25 x 1 in. (1)14 x 25 x 1 in. (1)
17-1/2 in.16 x 25 x 1 in. (1)16 x 25 x 1 in. (1)
21 in.16 x 25 x 1 in. (1)20 x 25 x 1 in. (1)
24-1/2 in.16 x 25 x 1 in. (2)24 x 25 x 1 in. (1)

Number in brackets is filter quantity; filters are field supplied.

Never run the unit without a filter installed.

Models that show this code

34 models in EL296UHV, Lennox SL280UHV, Lennox SL280UHNV, Lennox SL297NV, Lennox ML180UHE

EL296UH045XV36BEL296UH070XV36BEL296UH090XV36CEL296UH090XV48CEL296UH090XV60CEL296UH110XV48CEL296UH110XV60CEL296UH135XV60DML180UH045E36AKML180UH045XE36AKML180UH070E36AKML180UH070E36BKML180UH070XE36AKML180UH070XE36BKML180UH090E48BKML180UH090E60CKML180UH090XE48BKML180UH110E60CKML180UH110XE60CKML180UH135E60DKSL280UH060NV36ASL280UH070V36ASL280UH080NV48BSL280UH080NV60CSL280UH090V36BSL280UH090V48BSL280UH090V60CSL280UH100NV60CSL280UH110V60CSL280UH135V60DSL297UH040NV36BSL297UH060NV36BSL297UH080NV48CSL297UH080NV60C

Other codes on the same units

  • LGWP Test button Low GWP refrigerant detection board: modes and Test button
  • P Program unit size (button menu)
  • Power-up size code Unit size code shown at power-up (variable speed)
  • U Discharge air temperature
  • d Dehumidification mode
  • dF Defrost mode
  • h Heat pump stage (dual fuel)
  • ≡ Three bars - back to normal

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Lennox SL297UHNV Installation 507760-02 (02-2018), Integrated Control Diagnostic Modes, printed p.54; also SL280UHV 508245-01 p.51, SL280UHNV 1601-L8 Table 4, ML180UHEK 100166 p.12. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.