Fujitsu · Heat pump

Custom code A/B/C/D Wireless remote custom code display

Menu / mode display Fujitsu wall-mounted 7-15 (NA ASU/AOU type)Fujitsu slim duct ARU 7-18 (LL type)

What the display is showing

The wireless remote can be set to one of four custom codes, A to D, and the indoor unit only answers to the same code. The remote shows the current code when you hold MODE for 5 seconds or more. Shipping default is A, and the remote returns to A when its batteries are replaced.

Applies to: Fujitsu ductless heat pumps: Fujitsu wall-mounted 7-15 (NA ASU/AOU type); Fujitsu ductless heat pumps: Fujitsu slim duct ARU 7-18 (LL type)

What to do

  1. Press START/STOP until only the clock shows on the remote.
  2. Hold MODE for 5 seconds or more to show the current code.
  3. Press SET TEMP up or down to cycle A, B, C, D.
  4. Press MODE again to return to the clock and store it.
  5. If no key is pressed within 30 seconds the remote goes back to the clock without a change.

Settings for these units

Other codes on the same units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Fujitsu Wall-mounted 7-9-12-15 (North American trilingual, UTY-RNNUM remotes; e.g. ASU9-12-15 RLF1-RLS familie.pdf - section 11 Function setting, step 1 and remote controller custom code setting; Fujitsu Slim duct AR07-09-12-14-18 (ARU-ARYG LL-type equivalent) installation P-N 9381858064.pdf - section 13 Customer guidance. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.