Fujitsu · Heat pump

OPERATION + TIMER lamps flash together Test run / forced cooling running

Normal status Fujitsu wall-mounted 7-15 (NA ASU/AOU type)Fujitsu multi-zone outdoor 18/24 type

What the display is showing

The green OPERATION lamp and the orange TIMER lamp flash at the same time while the unit is in test run or forced cooling. It is normal and means the test run was started from the remote TEST RUN key or by holding MANUAL AUTO. It is not an error code. The wall-unit manual also mentions a slow simultaneous flash while a test run started with the remote's test run key is running.

Applies to: Fujitsu ductless heat pumps: Fujitsu wall-mounted 7-15 (NA ASU/AOU type); Fujitsu ductless heat pumps: Fujitsu multi-zone outdoor 18/24 type (18 type 2-zone, 24 type 3-zone)

Settings for these units

Operating range and service space · Fujitsu multi-zone outdoor 18/24 type

ItemValue
Cooling outdoor range14 to 115 F DB
Heating outdoor range5 to 75 F DB
Cooling indoor range65 to 90 F DB
Heating indoor range60 to 88 F DB
Rear (open top, rear wall only)4 in. or more
Rear + sides4 in. rear, 10 in. sides
Front wall only24 in. or more
Between side-by-side units10 in. or more
Base height2 in. or more above floor

Unit tilt no more than 3 degrees and never toward the compressor side.

Below 32 F outdoor do not fit the drain pipe/caps (freezing).

Other codes on the same units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Fujitsu Wall-mounted 7-9-12-15 (North American trilingual, UTY-RNNUM remotes; e.g. ASU9-12-15 RLF1-RLS familie.pdf - section 12 Test run; Fujitsu Outdoor unit 18-24 type (North American trilingual) installation P-N 9374747160.pdf - section 9 Pump down operation. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.