Fujitsu · Heat pump

15 Check run unfinished / airflow auto-adjust error

Low severity Fujitsu ductless split/multi/VRF (general code list)Fujitsu wall-mounted 7-15 (NA ASU/AOU type)Fujitsu slim duct ARU 7-18 (LL type)

What the control is telling you

The commissioning check run has not been completed (on ducted units this also covers a failed automatic airflow adjustment). Indoor lamps: OPERATION (green) flashes 1x, TIMER (orange) flashes 5x, ECONOMY (green) flashes fast nonstop; wired remote shows 15.

Applies to: Fujitsu ductless heat pumps: Fujitsu ductless split/multi/VRF (general code list), Fujitsu wall-mounted 7-15 (NA ASU/AOU type), Fujitsu slim duct ARU 7-18 (LL type)

Likely causes

  • Test run / check run not finished after install
  • Duct static outside the unit range during auto adjust

Test and repair steps

  1. Complete the check run / test run per the install manual.
  2. On ducted units check duct static and filters, then repeat the airflow auto-adjust or set static pressure manually (function 26).

Settings for these units

Other codes on the same units

  • 9U Outdoor unit error (general)
  • 11 Serial communication error (indoor/outdoor)
  • 12 Wired remote controller communication error
  • 14 Network communication error
  • 16 Peripheral unit / transmission PCB connection error
  • 21 Address / refrigerant circuit setting error
  • 22 Indoor unit capacity error
  • 23 Combination error

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Fujitsu All Fujitsu split - multi - VRF (generic code list) codes.pdf - section error code table (indoor LED flashes); Fujitsu Wall-mounted 7-9-12-15 (North American trilingual, UTY-RNNUM remotes; e.g. ASU9-12-15 RLF1-RLS familie.pdf - section 14 Error codes; Fujitsu Slim duct AR07-09-12-14-18 (ARU-ARYG LL-type equivalent) installation P-N 9381858064.pdf - section 14 Error codes. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.