FlowMax · Combi boiler

Winter mode symbol Winter mode selected (heating only)

Normal status FlowMax condensing combi (FLOWMAX-90/120)

What the display is showing

The winter-mode symbol stays lit steadily when winter mode is chosen. The unit then serves only central heating. The symbol flashes while the burner is running for a room heating demand.

Applies to: FLOWMAX-90 and FLOWMAX-120 combi

Settings for these units

Installation clearances · FlowMax condensing combi (FLOWMAX-90/120)

LocationService clearance (in)To combustibles
X (side)00 in
Y (side)00 in
L16-
H24-
A (above)120 in from jacket top
B (below)12-
Front-0 in
Rear-0 in

Wall-mount on a flat, solid vertical wall that can carry the weight.

Letters follow fig. 1 of the manual; L and H are the clearance zone in front/around the unit as drawn.

Hot water scald risk by temperature · FlowMax condensing combi (FLOWMAX-90/120)

Temperature settingTime to 2nd/3rd degree burn (adult skin)
Over 170°FNearly instantaneous
160°FAbout 1/2 second
150°FAbout 1-1/2 seconds
140°FLess than 5 seconds
130°FAbout 30 seconds
120°F or lessMore than 5 minutes

120°F lowers scald risk; children, elderly and disabled people burn faster.

Fit a tempering (mixing) valve if water is stored or set hotter, e.g. with parameter 1 = 03 (up to 160°F).

Models that show this code

2 models in FlowMax condensing combi (FLOWMAX-90/120)

FLOWMAX-120FLOWMAX-90

Other codes on the same units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: FLOWMAX-90 User Manual, Starting-up / Winter mode, p.7; FLOWMAX-120 Instruction Manual, 4.5 Starting up, p.38. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.