Bosch · Tankless water heater
EC Flame lost during operation
What the control is telling you
The flame went out while heating.
Applies to: Bosch Greentherm T9800 SE 160/199 and T9900 SE 160/199 / i 199 tankless water heaters
Likely causes
- Low gas inlet pressure
- Combustion out of adjustment
Test and repair steps
- Check gas inlet pressure.
- Run the gas and air tuning procedure.
Models that show this code
6 models in Bosch Greentherm T9800 SE, Bosch Greentherm T9900 SE
Other codes on the same units
- DH DH data history
- Display blank Display blank - appliance off
- EA Ignition failure
- EB Control unit internal error
- EE Gas valve modulation coil disconnected
- EF Wrong gas type configured
- Error reset Hold ON/OFF key to clear an error code
- FA Gas leak in the gas path
Sequence of operation
What the unit does around this code, step by step.
- Flow-activated hot water call · Domestic hot water
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Bosch Greentherm T9800 SE 160/199 installation 6720816815 (06.2023), Table 24 Error code diagnostics, p.65-69; Bosch Greentherm T9900 SE 160/199 | i 199 installation 6 720 813 635 (2024-06), section 9.1 Error code diagnostics, p.68-73. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.