Bosch · Tankless water heater
EE Gas valve modulation coil disconnected
What the control is telling you
The modulating solenoid on the gas valve is not connected.
Applies to: Bosch Greentherm T9800 SE 160/199 and T9900 SE 160/199 / i 199 tankless water heaters
Likely causes
- Loose gas valve connector
- Failed gas valve or control board
Test and repair steps
- Check the gas valve connector.
- Replace the gas valve, wiring or control unit if it persists; after a valve change run the gas and air tuning.
Models that show this code
6 models in Bosch Greentherm T9800 SE, Bosch Greentherm T9900 SE
Other codes on the same units
- Display blank Display blank - appliance off
- EA Ignition failure
- EB Control unit internal error
- EC Flame lost during operation
- EF Wrong gas type configured
- Error reset Hold ON/OFF key to clear an error code
- FA Gas leak in the gas path
- FC Touch key held over 20 seconds
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Bosch Greentherm T9800 SE 160/199 installation 6720816815 (06.2023), Table 24 Error code diagnostics, p.65-69; Bosch Greentherm T9900 SE 160/199 | i 199 installation 6 720 813 635 (2024-06), section 9.1 Error code diagnostics, p.68-73. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.