Beckett · Boiler
Yellow light solid Pump prime mode (or reset held 15 s)
What the display is showing
Solid yellow means the control is in Pump Prime mode, or the reset button has been held for more than 15 seconds. In Pump Prime the motor, igniter and oil valve run for 4 minutes and the cad cell is ignored, so you can bleed the pump without jumping the cad cell.
Applies to: Beckett NX burner with GeniSys 7505 primary control on Weil-McLain Ultra Oil UO-3, UO-4, UO-5 (CV and DV)
Good to know
- Technician put the control in Pump Prime
- Reset button held down 15 s or longer
What to do
- Bleed the pump while the yellow light is on.
- To leave Pump Prime early, click the reset button once; the control goes back to standby.
Other codes on the same units
- Green light flashing Recycle - flame lost while running
- Green light solid Flame sensed
- Red light flashing Soft lockout - no flame proved
- Red light solid Restricted (hard) lockout
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Beckett NX Burner Manual for Weil-McLain Ultra Oil boilers (W-M 550-141-996/0321), Table 5 Status Lights and Table 4 Reset Button p.13; Pump Prime p.12. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.