Noritz · Tankless water heater · Pump/purge

Other recirculation modes

NRCR Pro

What happens, in order

  1. Manual Timer set the hours the pump runs with the app, copy one day to all weekdays
  2. On Demand (Title 24) pump runs only when a push button (WLB), motion sensor (WLB-MS) or rocker switch (IHK-RS) is activated
  3. Always Off pump never runs
  4. Always On pump runs continuously
  5. Crossover valve systems need a set temperature of at least 120 F
  6. Check the active mode with maintenance monitor MM86

Codes you may see during this

06 63

Applies to: Noritz NRCR92, NRCR111 (NRCR Pro)

Models

NRCR92NRCR111

More Noritz tankless water heater sequences

Take it to the job

Sequences of operation, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Noritz NRCR Pro Residential Condensing Recirculation training (NRCR Printable V3), recirculation modes section; Premix R2 training MM86 page. Written in our own words; timings can differ by model and software version, so check the manual for your exact unit.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.