Noritz · technician tips

Noritz service menus, test modes and resets

8 tips for tankless water heater: access codes, button combinations, test modes and the resets you need at the appliance.

Jump to: Access & passwords (1) · Service & test modes (1) · Reset & cancel (1) · Settings shortcuts (1) · Other (4)

Access & passwords

Installer and service menu codes, and how to get into them.

Recover a forgotten screen lock password

Tankless water heater · Noritz EZ, Noritz NRCR

The operation panel screen lock uses a 4-digit password.

  1. When 'Input Password' is shown, hold OK for about 5 seconds.

Applies to: Noritz EZ111/EZ98/EZ71 and NRCR111/NRCR92

Source: Noritz EZ/NRCR Owner's Guide (Rev. 10-25), Configuring settings using the operation panel, p.15-20. Written in our own words; check the manual for your exact model.

Service & test modes

Forced fan, low and high fire, test and diagnostic modes, error history and live data.

Trial operation of parts (EZ Start Plus app)

Tankless water heater · Noritz EZ, Noritz NRCR, Noritz CDV

Switch individual parts on and off to check them: fan motor, igniter, water servo, pump (NRCR only) and bypass servo (CDV only), depending on the unit.

  1. Open EZ Start Plus and connect.
  2. Tap Maintenance, then Trial Operation.
  3. Pick the part and tap the toggle to turn it on, tap again to turn it off.

Applies to: EZ, NRCR, CDV (Pro units with EZ Start Plus app)

Source: Noritz EZ/NRCR/CDV Level 2 Maintenance & Troubleshooting (Premix R2 V2), Trial Operation, p.23. Written in our own words; check the manual for your exact model.

Reset & cancel

Clearing lockouts, service reminders and fault history; skipping purge or de-air programs.

Reset the panel settings to defaults (Default Settings)

Tankless water heater · Noritz EZ, Noritz NRCR

Default Settings resets everything in Settings except Screen Lock.

  1. Open Settings and choose Default Settings.
  2. Hold OK for about 5 seconds.

Applies to: Noritz EZ111/EZ98/EZ71 and NRCR111/NRCR92

Source: Noritz EZ/NRCR Owner's Guide (Rev. 10-25), Configuring settings using the operation panel, p.15-20. Written in our own words; check the manual for your exact model.

Settings shortcuts

Where the useful parameters live and what they are set to from the factory.

Set a temperature of 125 F (55 C) or higher

Tankless water heater · Noritz EZ, Noritz NRCR

Settings of 125 F (55 C) or higher need the Max Set Temperature raised first; the panel warns about scald risk.

  1. With the unit power off, raise Max Set Temperature (100-140 F, default 120 F / 50 C).
  2. Then set the temperature to 125 F (55 C) or higher.

Applies to: Noritz EZ111/EZ98/EZ71 and NRCR111/NRCR92

Source: Noritz EZ/NRCR Owner's Guide (Rev. 10-25), Configuring settings using the operation panel, p.15-20. Written in our own words; check the manual for your exact model.

Other

Everything else worth knowing at the appliance.

Check the recirculation mode (MM86)

Tankless water heater · Noritz NRCR

MM86 confirms which recirculation mode the unit is really set to.

  1. Open the maintenance monitor and select MM86.
  2. Read the value: dedicated return 11 Auto Recirc (default), 12 Manual timer, 13 Always ON, 14 Always OFF, 15 On-Demand (Title 24).
  3. Crossover valve units show 21 to 25 for the same modes in the same order.

Applies to: NRCR92, NRCR111

Source: Noritz EZ/NRCR/CDV Level 2 (Premix R2 V2), MM86 Recirculation Mode, p.21. Written in our own words; check the manual for your exact model.

Read live data (Maintenance Monitor)

Tankless water heater · Noritz EZ, Noritz NRCR

The Maintenance Monitor menu shows live unit data as MM numbers.

  1. Press the Menu button.
  2. Use Up/Down to select Maintenance Monitor, press OK.
  3. Pick the MM item to read.
  4. Press Back to leave.

Applies to: EZ111, EZ98, EZ71, NRCR111, NRCR92 (operation panel and RC-7651M-B remote)

Source: Noritz EZ/NRCR Owner's Guide (Rev. 10-25), Configuring Settings: Maintenance Monitor, p.20. Written in our own words; check the manual for your exact model.

Read the error history

Tankless water heater · Noritz EZ, Noritz NRCR

Shows the eight most recent failures, 1 being the newest.

  1. Press the Menu button.
  2. Open Maintenance Monitor.
  3. Select an error and press OK for details.

Applies to: EZ111, EZ98, EZ71, NRCR111, NRCR92 (operation panel and RC-7651M-B remote)

Source: Noritz EZ/NRCR Owner's Guide (Rev. 10-25), Configuring Settings: Maintenance Monitor / error history, p.20. Written in our own words; check the manual for your exact model.

Read the error history through maintenance monitors MM91-MM98

Tankless water heater · Noritz NRCR

On NRCR units the error history is also read in maintenance monitor mode.

  1. Open the maintenance monitor.
  2. MM91 is the most recent error code.
  3. MM92 to MM98 are error codes 2 to 8, next most recent first.

Applies to: Noritz NRCR92 / NRCR111

Source: Noritz NRCR Pro training (NRCR92/NRCR111, Printable V3), Commonly used maint monitors, p.35. Written in our own words; check the manual for your exact model.

Same tips in your pocket

The HVACopedia app has these tips, every error code and the settings tables offline.

Open the app

For licensed technicians. Installer menus, test modes and access codes change settings that affect safety; only use them if you are trained on the appliance and understand the result. Gas, electrical and refrigerant work must be done by a qualified, licensed person, and the manufacturer’s manual for the exact model and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.