Navien · Furnace · NPF700 series

NPF700-100U5CH parts

31 replacement parts that fit the Navien NPF700-100U5CH, with OEM part numbers, grouped by system.

Electrical

PartPart #QtySize / rating
Power Transformer
Service code 30025710*
30025710A1
Display Panel
Service code 30033143*
30031077A1
Main PCB
Service code 30033149*
30030898A1
PCB (Terminal)
Service code 30031078*. Use 30031078A for units after July 15, 2024 Replaces / alternate: 30031078A (after July 15, 2024).
30031078B1

Condensate

PartPart #QtySize / rating
Condensate Trap
Service code 30032013*
30032013A1

Other

PartPart #QtySize / rating
Upper Front Cover
Service code 30034546*
30031448D1
Bottom Front Cover
Service code 30034549*
30031449B1
Water Refill Cover
Service code 30031288*
30031288B1
Door Switch
Service code 30032939*
30034595A1
Condensate Drain Hose
Service code 30031476*
30031476A1
Pressure Relief Valve Adapter
No service code listed
30025921A1
Exhaust Vent Collar
Service code 30024848*
30024848B1
Intake Air Vent Collar
Service code 30008662*
30008662B1
Intake Air Filter
Service code 30030971*
30030971A1
Circulator Blower Assembly
Service code 30033170*
30031385A1
Hydronic Heat Exchanger
Service code 30033151*
30031352A1
Upper Cover
No service code listed
20061685A1
Pressure Relief Valve
Service code 30010376*
30010376A1
Auto Fill Valve
Service code 30030441*
30030441A1
Hot Water Joint Pipe
Service code 30031354*
30031354A1
Return Pipe
Service code 30031379*
30031379A1
Upper Vestibule Panel
Service code 30033183*
30031737A1
Lower Vestibule Panel
Service code 30033184*
20060583A1
Connection Adapter
Service code 30031511*
30031511A1
Supply Air Temperature Sensor
Service code 30033139*
30042322A1
VID Sensor
Service code 30024849*
30024849A1
Harness
Service code 30031164*. Listed harness, part name not given
30031164A1
Harness
Service code 30031159*. Listed harness, part name not given
30031159A1
Harness
Service code 30031162*. Listed harness, part name not given
30031162A1
Harness
Service code 30031160*. Listed harness, part name not given
30031160A1
Harness
Service code 30031161*. Listed harness, part name not given
30031161A1

Same series

The NPF700 parts list shows every part for all 7 models side by side. Other models: NPF700-060H3BH, NPF700-060H3BH (NPF700-60H), NPF700-060U3BH, NPF700-060U3BH (NPF700-60U), NPF700-080H3BH, NPF700-080U3BH.

Source: Navien NPF installation and operation manual, p. 152 (page 150). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.