Navien · Furnace parts

Navien NPF700: parts list

100 replacement parts with OEM part numbers for 7 models. Pick your model for a list of only the parts that fit it.

Jump to: Electrical · Condensate · Other

Electrical

PartPart #FitsQtySize / rating
Power Transformer
Service code 30025710*
30025710ANPF700-060U3BH, NPF700-080U3BH1
Display Panel
Service code 30033143*
30031077ANPF700-060U3BH, NPF700-080U3BH1
Main PCB
Service code 30033149*
30030898ANPF700-060U3BH, NPF700-080U3BH1
PCB (Terminal)
Service code 30031078*. Use 30031078A for units after July 15, 2024 Replaces / alternate: 30031078A (after July 15, 2024).
30031078BNPF700-060U3BH, NPF700-080U3BH1
Power Transformer
Service code 30025710*
30025710ANPF700-100U5CH1
Display Panel
Service code 30033143*
30031077ANPF700-100U5CH1
Main PCB
Service code 30033149*
30030898ANPF700-100U5CH1
PCB (Terminal)
Service code 30031078*. Use 30031078A for units after July 15, 2024 Replaces / alternate: 30031078A (after July 15, 2024).
30031078BNPF700-100U5CH1
Main PCB
Service code 30033149*
30030898ANPF700-060H3BH, NPF700-080H3BH1
Display Panel
Service code 30033143*
30031077ANPF700-060H3BH, NPF700-080H3BH1
Display Panel Bracket
No service code listed
20060818ANPF700-060H3BH, NPF700-080H3BH1
Power Transformer
Service code 30025710*
30025710ANPF700-060H3BH, NPF700-080H3BH1
PCB (Terminal)
Service code 30031078*
30031078BNPF700-060H3BH, NPF700-080H3BH1

Condensate

PartPart #FitsQtySize / rating
Condensate Trap
Service code 30032013*
30032013ANPF700-060U3BH, NPF700-080U3BH1
Condensate Trap
Service code 30032013*
30032013ANPF700-100U5CH1
Condensate Joint Hose
Service code 30032595*
30032595ANPF700-060H3BH, NPF700-080H3BH1
Condensate Trap
Service code 30032468*
30032468ANPF700-060H3BH, NPF700-080H3BH1
Condensate Drain Hose Cover
Service code 20061987*
20061987ANPF700-060H3BH, NPF700-080H3BH1
Condensate Drain Hose
Service code 30032271*
30032271ANPF700-060H3BH, NPF700-080H3BH1
Condensate Trap Hose Guide
Service code 20062200*
20062200ANPF700-060H3BH, NPF700-080H3BH1

Other

PartPart #FitsQtySize / rating
Upper Front Cover
Service code 30034544*
30031437DNPF700-060U3BH, NPF700-080U3BH1
Bottom Front Cover
Service code 30033145*. For NPF700-80U: Part # 30038884C, service code 30042461* Replaces / alternate: 30038884C (NPF700-80U).
30031438BNPF700-060U3BH (NPF700-60U)1
Water Refill Cover
Service code 30031288*
30031288BNPF700-060U3BH, NPF700-080U3BH1
Door Switch
Service code 30032939*
30034595ANPF700-060U3BH, NPF700-080U3BH1
Condensate Drain Hose
Service code 30031476*
30031476ANPF700-060U3BH, NPF700-080U3BH1
Pressure Relief Valve Adapter
No service code listed
30025921ANPF700-060U3BH, NPF700-080U3BH1
Exhaust Vent Collar
Service code 30024848*
30024848BNPF700-060U3BH, NPF700-080U3BH1
Intake Air Vent Collar
Service code 30008662*
30008662BNPF700-060U3BH, NPF700-080U3BH1
Intake Air Filter
Service code 30030971*
30030971ANPF700-060U3BH, NPF700-080U3BH1
Circulator Blower Assembly
Service code 30033166*
30031384ANPF700-060U3BH, NPF700-080U3BH1
Hydronic Heat Exchanger
Service code 30033147*
30041525ANPF700-060U3BH, NPF700-080U3BH1
Upper Cover
No service code listed
30035388ANPF700-060U3BH, NPF700-080U3BH1
Pressure Relief Valve
Service code 30010376*
30010376ANPF700-060U3BH, NPF700-080U3BH1
Auto Fill Valve
Service code 30030441*
30030441ANPF700-060U3BH, NPF700-080U3BH1
Hot Water Joint Pipe
Service code 30031968*
30041646ANPF700-060U3BH, NPF700-080U3BH1
Return Pipe
Service code 30031969*
30041647ANPF700-060U3BH, NPF700-080U3BH1
Upper Vestibule Panel
Service code 30033181*
30041261ANPF700-060U3BH, NPF700-080U3BH1
Lower Vestibule Panel
Service code 30033182*
20082070ANPF700-060U3BH, NPF700-080U3BH1
Connection Adapter
Service code 30031511*
30031511ANPF700-060U3BH, NPF700-080U3BH1
Supply Air Temperature Sensor
Service code 30033139*
30042322ANPF700-060U3BH, NPF700-080U3BH1
VID Sensor
Service code 30024849*
30024849ANPF700-060U3BH, NPF700-080U3BH1
Harness
Service code 30031164*. Listed harness, part name not given
30031164ANPF700-060U3BH, NPF700-080U3BH1
Harness
Service code 30031159*. Listed harness, part name not given
30031159ANPF700-060U3BH, NPF700-080U3BH1
Harness
Service code 30031162*. Listed harness, part name not given
30031162ANPF700-060U3BH, NPF700-080U3BH1
Harness
Service code 30031160*. Listed harness, part name not given
30031160ANPF700-060U3BH, NPF700-080U3BH1
Harness
Service code 30031161*. Listed harness, part name not given
30031161ANPF700-060U3BH, NPF700-080U3BH1
Upper Front Cover
Service code 30034546*
30031448DNPF700-100U5CH1
Bottom Front Cover
Service code 30034549*
30031449BNPF700-100U5CH1
Water Refill Cover
Service code 30031288*
30031288BNPF700-100U5CH1
Door Switch
Service code 30032939*
30034595ANPF700-100U5CH1
Condensate Drain Hose
Service code 30031476*
30031476ANPF700-100U5CH1
Pressure Relief Valve Adapter
No service code listed
30025921ANPF700-100U5CH1
Exhaust Vent Collar
Service code 30024848*
30024848BNPF700-100U5CH1
Intake Air Vent Collar
Service code 30008662*
30008662BNPF700-100U5CH1
Intake Air Filter
Service code 30030971*
30030971ANPF700-100U5CH1
Circulator Blower Assembly
Service code 30033170*
30031385ANPF700-100U5CH1
Hydronic Heat Exchanger
Service code 30033151*
30031352ANPF700-100U5CH1
Upper Cover
No service code listed
20061685ANPF700-100U5CH1
Pressure Relief Valve
Service code 30010376*
30010376ANPF700-100U5CH1
Auto Fill Valve
Service code 30030441*
30030441ANPF700-100U5CH1
Hot Water Joint Pipe
Service code 30031354*
30031354ANPF700-100U5CH1
Return Pipe
Service code 30031379*
30031379ANPF700-100U5CH1
Upper Vestibule Panel
Service code 30033183*
30031737ANPF700-100U5CH1
Lower Vestibule Panel
Service code 30033184*
20060583ANPF700-100U5CH1
Connection Adapter
Service code 30031511*
30031511ANPF700-100U5CH1
Supply Air Temperature Sensor
Service code 30033139*
30042322ANPF700-100U5CH1
VID Sensor
Service code 30024849*
30024849ANPF700-100U5CH1
Harness
Service code 30031164*. Listed harness, part name not given
30031164ANPF700-100U5CH1
Harness
Service code 30031159*. Listed harness, part name not given
30031159ANPF700-100U5CH1
Harness
Service code 30031162*. Listed harness, part name not given
30031162ANPF700-100U5CH1
Harness
Service code 30031160*. Listed harness, part name not given
30031160ANPF700-100U5CH1
Harness
Service code 30031161*. Listed harness, part name not given
30031161ANPF700-100U5CH1
Left Front Cover
Service code 30033469*
30031881BNPF700-060H3BH, NPF700-080H3BH1
Right Front Cover
Service code 30033470*. For NPF700-80H: Part # 30038974A, service code 30042473* Replaces / alternate: 30038974A (NPF700-080H3BH).
30031883BNPF700-060H3BH (NPF700-60H)1
Water Refill Cover
Service code 30031288*
30031288BNPF700-060H3BH, NPF700-080H3BH1
Door Switch
Service code 30034595*
30034595ANPF700-060H3BH, NPF700-080H3BH1
Drain Adapter
No service code listed
30031900ANPF700-060H3BH, NPF700-080H3BH1
Auto Fill Valve
Service code 30030441*
30030441ANPF700-060H3BH, NPF700-080H3BH1
Pressure Relief Valve Adapter
No service code listed
30032834ANPF700-060H3BH, NPF700-080H3BH1
Pressure Relief Valve
Service code 30010376*
30010376ANPF700-060H3BH, NPF700-080H3BH1
Intake Vent Collar
Service code 30008662*
30008662BNPF700-060H3BH, NPF700-080H3BH1
Intake Air Filter
Service code 30030971*
30030971ANPF700-060H3BH, NPF700-080H3BH1
Exhaust Vent Collar
Service code 30024848*
30024848BNPF700-060H3BH, NPF700-080H3BH1
Upper Cover
No service code listed
30031893BNPF700-060H3BH, NPF700-080H3BH1
Hydronic Heat Exchanger
Service code 30033147*
30031351ANPF700-060H3BH, NPF700-080H3BH1
Circulator Blower Assembly
Service code 30033166*
30031384ANPF700-060H3BH, NPF700-080H3BH1
Return Pipe
Service code 30031633*
30031633ANPF700-060H3BH, NPF700-080H3BH1
Circulation Tube
Service code 30031639*
30031639ANPF700-060H3BH, NPF700-080H3BH1
Connection Adapter
Service code 30031511*
30031511ANPF700-060H3BH, NPF700-080H3BH1
Pump Inlet Pipe
Service code 30031637*
30031637ANPF700-060H3BH, NPF700-080H3BH1
Pump Outlet Pipe
Service code 30031635*
30031635ANPF700-060H3BH, NPF700-080H3BH1
Left Vestibule Panel
Service code 30033468*
30032167ANPF700-060H3BH, NPF700-080H3BH1
Right Vestibule Panel
Service code 30033466*
20060785ANPF700-060H3BH, NPF700-080H3BH1
Supply Air Temperature Sensor
Service code 30033139*
30042322ANPF700-060H3BH, NPF700-080H3BH1
VID Sensor
Service code 30024849*
30024849ANPF700-060H3BH, NPF700-080H3BH1
Harness
Service code 30031164*. Listed harness, part name not given
30031164ANPF700-060H3BH, NPF700-080H3BH1
Harness
Service code 30031925*. Listed harness, part name not given
30031925ANPF700-060H3BH, NPF700-080H3BH1
Harness
Service code 30031927*. Listed harness, part name not given
30031927ANPF700-060H3BH, NPF700-080H3BH1
Harness
Service code 30031926*. Listed harness, part name not given
30031926ANPF700-060H3BH, NPF700-080H3BH1
Harness
Service code 30031161*. Listed harness, part name not given
30031161ANPF700-060H3BH, NPF700-080H3BH1

Source: Navien NPF installation and operation manual, p. 152 (pages 148, 150, 152). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.