Navien · Furnace · NPF700 series
NPF700-080U3BH parts
30 replacement parts that fit the Navien NPF700-080U3BH, with OEM part numbers, grouped by system.
Electrical
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Power Transformer Service code 30025710* | 30025710A | 1 | |
| Display Panel Service code 30033143* | 30031077A | 1 | |
| Main PCB Service code 30033149* | 30030898A | 1 | |
| PCB (Terminal) Service code 30031078*. Use 30031078A for units after July 15, 2024 Replaces / alternate: 30031078A (after July 15, 2024). | 30031078B | 1 |
Condensate
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Condensate Trap Service code 30032013* | 30032013A | 1 |
Other
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Upper Front Cover Service code 30034544* | 30031437D | 1 | |
| Water Refill Cover Service code 30031288* | 30031288B | 1 | |
| Door Switch Service code 30032939* | 30034595A | 1 | |
| Condensate Drain Hose Service code 30031476* | 30031476A | 1 | |
| Pressure Relief Valve Adapter No service code listed | 30025921A | 1 | |
| Exhaust Vent Collar Service code 30024848* | 30024848B | 1 | |
| Intake Air Vent Collar Service code 30008662* | 30008662B | 1 | |
| Intake Air Filter Service code 30030971* | 30030971A | 1 | |
| Circulator Blower Assembly Service code 30033166* | 30031384A | 1 | |
| Hydronic Heat Exchanger Service code 30033147* | 30041525A | 1 | |
| Upper Cover No service code listed | 30035388A | 1 | |
| Pressure Relief Valve Service code 30010376* | 30010376A | 1 | |
| Auto Fill Valve Service code 30030441* | 30030441A | 1 | |
| Hot Water Joint Pipe Service code 30031968* | 30041646A | 1 | |
| Return Pipe Service code 30031969* | 30041647A | 1 | |
| Upper Vestibule Panel Service code 30033181* | 30041261A | 1 | |
| Lower Vestibule Panel Service code 30033182* | 20082070A | 1 | |
| Connection Adapter Service code 30031511* | 30031511A | 1 | |
| Supply Air Temperature Sensor Service code 30033139* | 30042322A | 1 | |
| VID Sensor Service code 30024849* | 30024849A | 1 | |
| Harness Service code 30031164*. Listed harness, part name not given | 30031164A | 1 | |
| Harness Service code 30031159*. Listed harness, part name not given | 30031159A | 1 | |
| Harness Service code 30031162*. Listed harness, part name not given | 30031162A | 1 | |
| Harness Service code 30031160*. Listed harness, part name not given | 30031160A | 1 | |
| Harness Service code 30031161*. Listed harness, part name not given | 30031161A | 1 |
Same series
The NPF700 parts list shows every part for all 7 models side by side. Other models: NPF700-060H3BH, NPF700-060H3BH (NPF700-60H), NPF700-060U3BH, NPF700-060U3BH (NPF700-60U), NPF700-080H3BH, NPF700-100U5CH.
Source: Navien NPF installation and operation manual, p. 152 (page 148). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.