Navien · Boiler · NCB700 series
NCB700 all models parts
39 replacement parts that fit the Navien NCB700 all models, with OEM part numbers, grouped by system.
Other
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Air vent adapter | 30043830* | 1 | |
| Intake air duct assembly | 30043451* | 1 | |
| Exhaust duct assembly | 30024848* | 1 | |
| External base | 20081063* | 1 | |
| Base bracket | 20007609* | 1 | |
| Base lower bracket | 20007643* | 1 | |
| APS | 30021100* | 1 | |
| 24 V power transformer | 30025710* | 1 | |
| Main PCB | 30041247* | 1 | |
| Terminal PCB | 30041250* | 1 | |
| Front panel | 30041248* | 1 | |
| Front cover (A/S) | 30043283* | 1 | |
| Mixing chamber bracket | 20045107* | 1 | |
| Damper | 30043345* | 1 | |
| Exhaust duct assembly | 20047767* | 1 | |
| Thermistor (Exhaust) | 30009478* | 1 | |
| Igniter | 30042227* | 1 | |
| Ignition transformer | 30043452* | 1 | |
| Flame inspection window assembly | 30044260* | 1 | |
| High limit switch | 30002577* | 1 | |
| High limit switch bracket | 20088737* | 1 | |
| Pressure sensor | 30014699* | 1 | |
| Thermistor (Water) | 30008366* | 1 | |
| Condensate neutralizer kit Optional accessory | GXXX002212 | 1 | |
| Zone controller (FMZ-40/60) Optional accessory. X in the part number is the zone count (2/3/4/5/6). | PFMZ-0XP-001 | 1 | 40/60 |
| Zone controller (FMZ-20/30) Optional accessory. X in the part number is the zone count (2/3/4/5/6). The asterisk is printed in the manual and its meaning is not explained on these pages. | PFMZ-0XP-001* | 1 | 20/30 |
| Universal temperature sensor (with clip) Optional. Can be used as the system temperature sensor or the DHW tank sensor. | GXXX001769 | 1 | |
| Ready-Link bracket Optional accessory. | GFFM-KDIZUS-007 (GFFM-KDIZUS-008 for add-ons) | 1 | |
| Navien intake system Optional accessory. | GXXX003030 | 1 | |
| NaviClean Optional accessory. | GXXX001727 | 1 | |
| HotButton kit Optional accessory. | PZZZ-00063 | 1 | |
| Condensate neutralizer kit Optional | GXXX002212 | 1 | |
| Zone controller FMZ-40/60 Optional | PFMZ-0XP-001 | 1 | 4 to 6 zones (X = 2 to 6) |
| Zone controller FMZ-20/30 Optional; asterisk on the part number is printed in the source | PFMZ-0XP-001* | 1 | 2 to 3 zones (X = 2 to 3) |
| Universal temperature sensor (with clip) Can be used as a system sensor or DHW tank sensor | GXXX001769 | 1 | |
| Ready-Link bracket GFFM-KDIZUS-008 is used for add-ons Replaces / alternate: GFFM-KDIZUS-008 (add-ons). | GFFM-KDIZUS-007 | 1 | |
| Navien intake system Optional | GXXX003030 | 1 | |
| NaviClean Optional | GXXX001727 | 1 | |
| HotButton kit Optional | PZZZ-00063 | 1 |
Same series
The NCB700 parts list shows every part for all 13 models side by side. Other models: All NCB700, All models, NCB700, NCB700-190/060, NCB700-190/080, NCB700-190/080 (LP), NCB700-190/080 (NG), NCB700-240/110, NCB700-240/130, NCB700-250/150, NCB700-250/150 (LP), NCB700-250/150 (NG).
Source: Navien NCB700 installation and operation manual, p. 152 (pages 150, 152, 168). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.