Navien · Boiler parts

Navien NCB700: parts list

153 replacement parts with OEM part numbers for 13 models. Pick your model for a list of only the parts that fit it.

Jump to: Other

Other

PartPart #FitsQtySize / rating
Internal circulation pump (Grundfos UPS 15-78 CESAO3)
Factory default speed is Sp3; lowering speed may reduce space heating and DHW performance.
30042067ANCB700-190/060, NCB700-190/080, NCB700-240/110, NCB700-240/130, NCB700-250/1501
Common Vent Collar Kit (backdraft damper)
Polypropylene (PP). Includes backdraft damper and cascade cable.
30014367NCB70015.9 in (150 mm) / 1.1 in (28 mm) as printed
Natural gas altitude kit 0-5,399 ft
Natural gas, 0-5,399 ft
NAC-NCB700-190/080NNCB700-190/060, NCB700-190/0801
Natural gas high altitude kit 5,400-10,100 ft
Natural gas, 5,400-10,100 ft
NAC-NCB700-190/080NHNCB700-190/060, NCB700-190/0801
Propane gas altitude kit 0-10,100 ft
Propane gas, 0-10,100 ft
NAC-NCB700-190/080LPNCB700-190/060, NCB700-190/0801
Natural gas altitude kit 0-5,399 ft
Natural gas, 0-5,399 ft
NAC-NCB700-240/130NNCB700-240/110, NCB700-240/1301
Natural gas high altitude kit 5,400-10,100 ft
Natural gas, 5,400-10,100 ft
NAC-NCB700-240/130NHNCB700-240/110, NCB700-240/1301
Propane gas altitude kit 0-10,100 ft
Propane gas, 0-10,100 ft
NAC-NCB700-240/130LPNCB700-240/110, NCB700-240/1301
Natural gas altitude kit 0-5,399 ft
Natural gas, 0-5,399 ft
NAC-NCB700-250/150NNCB700-250/1501
Natural gas high altitude kit 5,400-10,100 ft
Natural gas, 5,400-10,100 ft
NAC-NCB700-250/150NHNCB700-250/1501
Propane gas altitude kit 0-10,100 ft
Propane gas, 0-10,100 ft
NAC-NCB700-250/150LPNCB700-250/1501
Air vent adapter30043830*All 13 models1
Intake air duct assembly30043451*All 13 models1
Exhaust duct assembly30024848*All 13 models1
External base20081063*All 13 models1
Base bracket20007609*All 13 models1
Base lower bracket20007643*All 13 models1
APS30021100*All 13 models1
24 V power transformer30025710*All 13 models1
Main PCB30041247*All 13 models1
Terminal PCB30041250*All 13 models1
Front panel30041248*All 13 models1
Front cover (A/S)30043283*All 13 models1
Mixing chamber30040581* (NCB700-190/080); 30040582* (NCB700-250/150)NCB700-190/080, NCB700-250/1501
Mixing chamber bracket20045107*All 13 models1
Damper30043345*All 13 models1
Burner gasket (Graphite)20079125* (NCB700-190/080); 20083171* (NCB700-250/150)NCB700-190/080, NCB700-250/1501
Burner gasket (Silicon)20079126* (NCB700-190/080); 20079127* (NCB700-250/150)NCB700-190/080, NCB700-250/1501
Exhaust duct assembly20047767*All 13 models1
Thermistor (Exhaust)30009478*All 13 models1
Condensate pan30024878* (NCB700-190/080); 30024879* (NCB700-250/150)NCB700-190/080, NCB700-250/1501
Heat exchanger assembly30041192* (NCB700-190/080); 30041193* (NCB700-250/150)NCB700-190/080, NCB700-250/1501
Igniter30042227*All 13 models1
Ignition transformer30043452*All 13 models1
Flame inspection window assembly30044260*All 13 models1
High limit switch30002577*All 13 models1
High limit switch bracket20088737*All 13 models1
Heat exchanger outlet pipe20088737* (NCB700-190/080); 30040572* (NCB700-250/150)NCB700-190/080, NCB700-250/1501
PCB bracket20085508* (NCB700-190/080); 20085509* (NCB700-250/150)NCB700-190/080, NCB700-250/1501
Return pipe30042240* (NCB700-190/080); 30042241* (NCB700-250/150)NCB700-190/080, NCB700-250/1501
Pressure sensor30014699*All 13 models1
Thermistor (Water)30008366*All 13 models1
Mixing chamber30040581*NCB700-190/0801
Mixing chamber30040582*NCB700-250/1501
Mixing chamber bracket20045107*All models1
Damper30043345*All models1
Burner gasket (Graphite)20079125*NCB700-190/0801
Burner gasket (Graphite)20083171*NCB700-250/1501
Burner gasket (Silicon)20079126*NCB700-190/0801
Burner gasket (Silicon)20079127*NCB700-250/1501
Exhaust duct assembly20047767*All models1
Thermistor (Exhaust)30009478*All models1
Condensate pan30024878*NCB700-190/0801
Condensate pan30024879*NCB700-250/1501
Heat exchanger assembly30041192*NCB700-190/0801
Heat exchanger assembly30041193*NCB700-250/1501
Igniter30042227*All models1
Ignition transformer30043452*All models1
Flame inspection window assembly30044260*All models1
High limit switch30002577*All models1
High limit switch bracket20088737*All models1
Heat exchanger outlet pipe20088737*NCB700-190/0801
Heat exchanger outlet pipe30040572*NCB700-250/1501
PCB bracket20085508*NCB700-190/0801
PCB bracket20085509*NCB700-250/1501
Return pipe30042240*NCB700-190/0801
Return pipe30042241*NCB700-250/1501
Pressure sensor30014699*All models1
Thermistor (Water)30008366*All models1
Plate heat exchanger30018297*NCB700-190/0801
Plate heat exchanger30043278*NCB700-250/1501
Mixing valve manifold20085181*All models1
O-ring (P14)20048004*All models1
Cap20017744*All models1
Thermistor30022222*All models1
Taptite screw (Φ4×12)20041461*All models1
Thermistor30023765*All models1
Taptite screw (Φ4×6)20017962*All models1
O-ring (P18)20048006*All models1
O-ring (P16)20048005*All models1
DHW outlet adapter20084299*All models1
Mixing adjust valve30041150*All models1
3-way valve body20085182*All models1
O-ring (P22A)20033699*All models1
Heating supply adapter20084297*All models1
3-way valve (A/S)-All models1
Clip20029414*All models1
Clip (Φ22.3)20033662*All models1
Clip (Φ18)20045992*All models1
O-ring (P26)20032409*All models1
Heating supply adapter gasket20083890*All models1
Mixing valve adapter20056229*All models1
Mixing connector20085185*All models1
Flow adjust valve30041151*All models1
DHW inlet connection adapter20056223*All models1
Clip (Φ19.2)20007733*All models1
Thermistor30022207*All models1
DHW inlet connection adapter20056579*All models1
Clip (Φ24.4)20007859*All models1
Plate heat exchanger bolt (M5×10)20009865*All models1
Plate heat exchanger gasket20047738*All models1
O-ring (17×4)20030919*All models1
Block plate20085231*All models1
Pump bolt (M5×10)20009830*All models1
Clip (Φ21.2)20035047*All models1
Bolt (M4×10)20038757*All models1
DHW inlet adapter gasket20045393*All models1
Circulation pump20083891*All models1
Fan30034246*All models1
O-ring (G75)20018079*All models1
Dual venturi30042259*NCB700-190/0801
Dual venturi30040935NCB700-250/1501
Venturi gasket20022660*All models1
Gas orifice (NG)
Natural gas
20083347*NCB700-190/080 (NG)1
Gas orifice (NG)
Natural gas
20083348*NCB700-250/150 (NG)1
Gas orifice (LP)
LP gas
20083349*NCB700-190/080 (LP)1
Gas orifice (LP)
LP gas
20083351*NCB700-250/150 (LP)1
O-ring (P34)20019090*All models1
Gas pipe (Out)30040575*NCB700-190/0801
Gas pipe (Out)30040576*NCB700-250/1501
Silence20031242*NCB700-190/0801
Silence20032570*NCB700-250/1501
Silence adapter20088123*NCB700-190/0801
Silence adapter20032569*NCB700-250/1501
Gas connector20018430*All models1
Gas connection gasket20058408*All models1
Gas control valve30030766*All models1
Gas pipe (In)20085967*All models1
Gas inlet adapter20042244*All models1
Condensate neutralizer kit
Optional accessory
GXXX002212All 13 models1
Zone controller (FMZ-40/60)
Optional accessory. X in the part number is the zone count (2/3/4/5/6).
PFMZ-0XP-001All 13 models140/60
Zone controller (FMZ-20/30)
Optional accessory. X in the part number is the zone count (2/3/4/5/6). The asterisk is printed in the manual and its meaning is not explained on these pages.
PFMZ-0XP-001*All 13 models120/30
Universal temperature sensor (with clip)
Optional. Can be used as the system temperature sensor or the DHW tank sensor.
GXXX001769All 13 models1
Ready-Link bracket
Optional accessory.
GFFM-KDIZUS-007 (GFFM-KDIZUS-008 for add-ons)All 13 models1
Navien intake system
Optional accessory.
GXXX003030All 13 models1
NaviClean
Optional accessory.
GXXX001727All 13 models1
HotButton kit
Optional accessory.
PZZZ-00063All 13 models1
Condensate neutralizer kit
Optional
GXXX002212NCB700 all models1
Zone controller FMZ-40/60
Optional
PFMZ-0XP-001NCB700 all models14 to 6 zones (X = 2 to 6)
Zone controller FMZ-20/30
Optional; asterisk on the part number is printed in the source
PFMZ-0XP-001*NCB700 all models12 to 3 zones (X = 2 to 3)
Universal temperature sensor (with clip)
Can be used as a system sensor or DHW tank sensor
GXXX001769NCB700 all models1
Ready-Link bracket
GFFM-KDIZUS-008 is used for add-ons Replaces / alternate: GFFM-KDIZUS-008 (add-ons).
GFFM-KDIZUS-007NCB700 all models1
Navien intake system
Optional
GXXX003030NCB700 all models1
NaviClean
Optional
GXXX001727NCB700 all models1
HotButton kit
Optional
PZZZ-00063NCB700 all models1
Condensate neutralizer kitGXXX002212All NCB7001
Zone controller (FMZ-40/60)
X in the part number indicates the number of zones (2/3/4/5/6).
PFMZ-0XP-001All NCB7001
Zone controller (FMZ-20/30)
X in the part number indicates the number of zones (2/3/4/5/6).
PFMZ-0XP-001*All NCB7001
Universal temperature sensor (with clip)
Can be used as a system temperature sensor or a DHW tank sensor.
GXXX001769All NCB7001
Ready-Link rack
GFFM-KDIZUS-008 is used for add-ons.
GFFM-KDIZUS-007All NCB7001
Navien manifold systemGXXX003030All NCB7001
NaviCleanGXXX001727All NCB7001
Hot Button kitPZZZ-00063All NCB7001

Source: Navien NCB700 installation and operation manual, p. 152 (pages 6, 8, 95, 144, 150, 152, 153, 154, 156, 168). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.