Navien · Boiler · NCB700 series

NCB700-250/150 parts

56 replacement parts that fit the Navien NCB700-250/150, with OEM part numbers, grouped by system.

Other

PartPart #QtySize / rating
Internal circulation pump (Grundfos UPS 15-78 CESAO3)
Factory default speed is Sp3; lowering speed may reduce space heating and DHW performance.
30042067A1
Natural gas altitude kit 0-5,399 ft
Natural gas, 0-5,399 ft
NAC-NCB700-250/150N1
Natural gas high altitude kit 5,400-10,100 ft
Natural gas, 5,400-10,100 ft
NAC-NCB700-250/150NH1
Propane gas altitude kit 0-10,100 ft
Propane gas, 0-10,100 ft
NAC-NCB700-250/150LP1
Air vent adapter30043830*1
Intake air duct assembly30043451*1
Exhaust duct assembly30024848*1
External base20081063*1
Base bracket20007609*1
Base lower bracket20007643*1
APS30021100*1
24 V power transformer30025710*1
Main PCB30041247*1
Terminal PCB30041250*1
Front panel30041248*1
Front cover (A/S)30043283*1
Mixing chamber30040581* (NCB700-190/080); 30040582* (NCB700-250/150)1
Mixing chamber bracket20045107*1
Damper30043345*1
Burner gasket (Graphite)20079125* (NCB700-190/080); 20083171* (NCB700-250/150)1
Burner gasket (Silicon)20079126* (NCB700-190/080); 20079127* (NCB700-250/150)1
Exhaust duct assembly20047767*1
Thermistor (Exhaust)30009478*1
Condensate pan30024878* (NCB700-190/080); 30024879* (NCB700-250/150)1
Heat exchanger assembly30041192* (NCB700-190/080); 30041193* (NCB700-250/150)1
Igniter30042227*1
Ignition transformer30043452*1
Flame inspection window assembly30044260*1
High limit switch30002577*1
High limit switch bracket20088737*1
Heat exchanger outlet pipe20088737* (NCB700-190/080); 30040572* (NCB700-250/150)1
PCB bracket20085508* (NCB700-190/080); 20085509* (NCB700-250/150)1
Return pipe30042240* (NCB700-190/080); 30042241* (NCB700-250/150)1
Pressure sensor30014699*1
Thermistor (Water)30008366*1
Mixing chamber30040582*1
Burner gasket (Graphite)20083171*1
Burner gasket (Silicon)20079127*1
Condensate pan30024879*1
Heat exchanger assembly30041193*1
Heat exchanger outlet pipe30040572*1
PCB bracket20085509*1
Return pipe30042241*1
Plate heat exchanger30043278*1
Dual venturi300409351
Gas pipe (Out)30040576*1
Silence20032570*1
Silence adapter20032569*1
Condensate neutralizer kit
Optional accessory
GXXX0022121
Zone controller (FMZ-40/60)
Optional accessory. X in the part number is the zone count (2/3/4/5/6).
PFMZ-0XP-001140/60
Zone controller (FMZ-20/30)
Optional accessory. X in the part number is the zone count (2/3/4/5/6). The asterisk is printed in the manual and its meaning is not explained on these pages.
PFMZ-0XP-001*120/30
Universal temperature sensor (with clip)
Optional. Can be used as the system temperature sensor or the DHW tank sensor.
GXXX0017691
Ready-Link bracket
Optional accessory.
GFFM-KDIZUS-007 (GFFM-KDIZUS-008 for add-ons)1
Navien intake system
Optional accessory.
GXXX0030301
NaviClean
Optional accessory.
GXXX0017271
HotButton kit
Optional accessory.
PZZZ-000631

Source: Navien NCB700 installation and operation manual, p. 152 (pages 8, 144, 150, 152, 153, 156, 168). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.