Majestic · Gas fireplace · DVBL7 series

400DVBLPV7 parts

14 replacement parts that fit the Majestic 400DVBLPV7, with OEM part numbers, grouped by system.

Ignition & flame

PartPart #QtySize / rating
Pilot assembly
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51.
37D00191
Replacement thermocouple
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51.
37D10671
Replacement igniter and wire
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51.
37D10691
Replacement thermopile
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51.
37D10681
Piezo igniter
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51.
14D05031

Gas valve & orifices

PartPart #QtySize / rating
Gas valve assembly
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51.
37D01181
Flex hose with shut-off valve
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51.
69D00301
Injector (orifice)
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51.
33D50391
Venturi
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51.
69D10261

Electrical

PartPart #QtySize / rating
Rocker switch
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51.
41D00481
Wire assembly
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51.
44D05001
Wire assembly (second harness)
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51.
44D05011

Heat exchanger & burners

PartPart #QtySize / rating
Burner tube
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51.
74D0049K1
Burner assembly
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51.
74D0098K1

Same series

The DVBL7 parts list shows every part for all 13 models side by side. Other models: 300DVBL, 300DVBLNSC7, 300DVBLPSC7, 400DVBL, 400DVBLNSC7, 400DVBLNV7, 400DVBLPSC7, 500DVBL, 500DVBLNSC7, 500DVBLNV7, 500DVBLPSC7, 500DVBLPV7.

Source: . Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.