Majestic · Gas fireplace · DVBL7 series

400DVBL parts

12 replacement parts that fit the Majestic 400DVBL, with OEM part numbers, grouped by system.

Gas valve & orifices

PartPart #QtySize / rating
Fuel conversion kit, natural gas to LP, 400DVBL
Replaces / alternate: Majestic DVBL7 manual 20301852, p.51 (millivolt fuel conversion kits).
BLCK400CKP1
Fuel conversion kit, LP to natural gas, 400DVBL
Replaces / alternate: Majestic DVBL7 manual 20301852, p.51 (millivolt fuel conversion kits).
BLCK400CKN1

Electrical

PartPart #QtySize / rating
Junction box assembly
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, firebox components, p.49.
26D2128K1

Motors & blowers

PartPart #QtySize / rating
Thermostat blower with speed control (field-installed option)
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, firebox components, p.49.
BLOTBLDV1
Blower with time delay for Signature Command system (field-installed option)
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, firebox components, p.49.
BLOTBCDVSC1

Heat exchanger & burners

PartPart #QtySize / rating
Firebrick set, Tavern Brown
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, firebox components, p.49.
FBBLDV400TB1
Firebrick set, Cottage Red
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, firebox components, p.49.
FBBLDV400CR1
Firebrick set, Olde English
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, firebox components, p.49.
FBBLDV400OE1

Cabinet & doors

PartPart #QtySize / rating
Sheet metal base
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, firebox components, p.49.
74D05141
Glass frame assembly
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, firebox components, p.49.
74D0096K1
Control cover
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, firebox components, p.49.
74D0038K1
Decorative mesh glass cover
Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, firebox components, p.49.
BLDV400SD1

Same series

The DVBL7 parts list shows every part for all 13 models side by side. Other models: 300DVBL, 300DVBLNSC7, 300DVBLPSC7, 400DVBLNSC7, 400DVBLNV7, 400DVBLPSC7, 400DVBLPV7, 500DVBL, 500DVBLNSC7, 500DVBLNV7, 500DVBLPSC7, 500DVBLPV7.

Source: . Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.