Majestic · Gas fireplace · DVBL7 series
400DVBLNV7 parts
14 replacement parts that fit the Majestic 400DVBLNV7, with OEM part numbers, grouped by system.
Ignition & flame
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Pilot assembly Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51. | 37D0018 | 1 | |
| Replacement thermocouple Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51. | 37D1067 | 1 | |
| Replacement igniter and wire Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51. | 37D1069 | 1 | |
| Replacement thermopile Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51. | 37D1068 | 1 | |
| Piezo igniter Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51. | 14D0503 | 1 |
Gas valve & orifices
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Gas valve assembly Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51. | 37D0117 | 1 | |
| Flex hose with shut-off valve Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51. | 69D0030 | 1 | |
| Injector (orifice) Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51. | 20H3147 | 1 | |
| Venturi Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51. | 69D1119 | 1 |
Electrical
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Rocker switch Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51. | 41D0048 | 1 | |
| Wire assembly Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51. | 44D0500 | 1 | |
| Wire assembly (second harness) Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51. | 44D0501 | 1 |
Heat exchanger & burners
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Burner tube Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51. | 74D0049K | 1 | |
| Burner assembly Replaces / alternate: Majestic DVBL7 Series Gas Fireplace manual 20301852, Replacement Parts, standing pilot millivolt control, pp.50-51. | 74D0098K | 1 |
Same series
The DVBL7 parts list shows every part for all 13 models side by side. Other models: 300DVBL, 300DVBLNSC7, 300DVBLPSC7, 400DVBL, 400DVBLNSC7, 400DVBLPSC7, 400DVBLPV7, 500DVBL, 500DVBLNSC7, 500DVBLNV7, 500DVBLPSC7, 500DVBLPV7.
Source: . Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.