Goodman · Furnace · GMVC8 series
GMVC80804CNBC parts
49 replacement parts that fit the Goodman GMVC80804CNBC, with OEM part numbers, grouped by system.
Controls & boards
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Integrated furnace control board | PCBKF105 | 1 | |
| Model data card for control board | 0130F00537 | 1 |
Ignition & flame
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Hot surface igniter, silicon nitride | 0130F00008 | 1 | |
| Flame sensor | 0130F00010 | 1 |
Gas valve & orifices
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Gas valve, two-stage | 0151M00027 | 1 | |
| Burner orifice | 10716005 | 3 | #45 drill |
| Gas manifold | 0120F00008 | 1 | |
| Orifice plate, 4 burner | 4028002 | 1 |
Pressure & limit switches
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Inducer pressure switch, two-stage | 0130F00570 | 1 | |
| Primary limit switch Goodman service bulletin SF-054 applies to this part | 20162904 | 1 | |
| Blower compartment limit (light blue) | 0130F00038 | 1 | 120 °F |
| Flame rollout switch, manual reset | 10123529 | 2 |
Electrical
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Transformer | 0130M00140 | 1 | 120 V to 24 V, 40 VA |
| Door interlock switch | 10690402 | 1 | |
| Inducer motor capacitor | DY6.186.070 | 1 | |
| Blower wire harness | 0259F00024 | 1 | |
| Blower power harness | 0259F00049 | 1 | |
| Wire harness | 0259M00008 | 1 | |
| Adapter harness | 0259M00005 | 1 | |
| Inducer harness | 0259F00062 | 1 | |
| Wire harness | 0259F00063 | 1 | |
| Wire harness | 0259F00081 | 1 |
Motors & blowers
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Blower motor, ECM | 0131M00270 | 1 | 1/2 HP |
| Blower housing with wheel | 0271F00303 | 1 | |
| Blower motor mount band, heavy duty | 0121M00039 | 1 | |
| Blower motor mount arm, heavy duty | B1376863 | 1 |
Inducer & venting
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Inducer (draft) motor, two-stage | 0131M00781P | 1 | |
| Flue collector box | 0121F00659 | 1 | 21 in., 1.40 in. outlet |
| Collector box gasket | 0154F00005 | 1 | 21 in. |
| Chimney transition, bottom | 0128F00006 | 1 | |
| Chimney transition, top | 4023500 | 1 |
Heat exchanger & burners
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Heat exchanger assembly | 0270F00930 | 1 | |
| Inshot burner, 3 in. | B4022700 | 3 | |
| Burner rack, 4 burner | 0121F00169 | 1 | |
| Burner box top, 4 burner | 0121F00164 | 1 | |
| Burner box side | 0121F00146 | 2 |
Cabinet & doors
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Blower door, painted | 0121F00124DG | 1 | 21 in. cabinet |
| Control access door, painted | 0121F00120DG | 1 | 21 in. cabinet |
| Furnace top, painted | 0121F00143DG | 1 | 21 in. cabinet |
| Control mounting panel | 0121F00218 | 1 | |
| Blower door view port bushing | B1392139 | 1 | |
| Universal bushing | B1392147 | 1 | |
| Junction box | 4014502 | 1 | |
| Junction box cover | 4015502 | 1 | |
| Nameplate | 0161F00007 | 1 |
Other
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Flat washer | B1392918 | 3 | 1/4 in. ID x 1 in. OD |
| Hex head tap bolt | 0163M00320 | 1 | |
| Screw | M0250565 | 3 | 1.25 in. |
| Locknut, nylon insert | B1393800 | 1 | 1/4-20 |
Same series
The GMVC8 parts list shows every part for all 22 models side by side. Other models: GMVC80603BNBC, GMVC80603BNBD, GMVC80603BXBC, GMVC80603BXBD, GMVC80604BNBD, GMVC80604BXBD, GMVC80803BNBC, GMVC80803BNBD, GMVC80803BXBC, GMVC80803BXBD, GMVC80804CNBD, GMVC80804CXBC, GMVC80804CXBD, GMVC80805CNBD, GMVC80805CXBD, GMVC80805DNBC, GMVC80805DNBD, GMVC80805DXBC, GMVC80805DXBD, GMVC81005CNBD, GMVC81005CXBD.
Source: Goodman repair parts manual RP-G2301A (July 2018) (pages 3, 5, 7, 9). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.