Goodman · Furnace parts
Goodman GMVC8 80% two-stage variable-speed furnace: parts list
105 replacement parts with OEM part numbers for 22 models. Pick your model for a list of only the parts that fit it.
Models
Jump to: Controls & boards · Ignition & flame · Gas valve & orifices · Pressure & limit switches · Electrical · Motors & blowers · Inducer & venting · Heat exchanger & burners · Cabinet & doors · Other
Controls & boards
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Integrated furnace control board | PCBKF105 | All 22 models | 1 | |
| Model data card for control board | 0130F00533 | GMVC80603BNBC, GMVC80603BNBD | 1 | |
| Model data card for control board | 0130F00534 | GMVC80603BXBC, GMVC80603BXBD | 1 | |
| Model data card for control board | 0130F00415 | GMVC80604BNBD | 1 | |
| Model data card for control board | 0130F00416 | GMVC80604BXBD | 1 | |
| Model data card for control board | 0130F00535 | GMVC80803BNBC, GMVC80803BNBD | 1 | |
| Model data card for control board | 0130F00536 | GMVC80803BXBC, GMVC80803BXBD | 1 | |
| Model data card for control board | 0130F00537 | GMVC80804CNBC, GMVC80804CNBD | 1 | |
| Model data card for control board | 0130F00538 | GMVC80804CXBC, GMVC80804CXBD | 1 | |
| Model data card for control board | 0130F00417 | GMVC80805CNBD | 1 | |
| Model data card for control board | 0130F00418 | GMVC80805CXBD | 1 | |
| Model data card for control board | 0130F00539 | GMVC80805DNBC, GMVC80805DNBD | 1 | |
| Model data card for control board | 0130F00540 | GMVC80805DXBC, GMVC80805DXBD | 1 | |
| Model data card for control board | 0130F00419 | GMVC81005CNBD | 1 | |
| Model data card for control board | 0130F00420 | GMVC81005CXBD | 1 |
Ignition & flame
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Hot surface igniter, silicon nitride | 0130F00008 | All 22 models | 1 | |
| Flame sensor | 0130F00010 | All 22 models | 1 |
Gas valve & orifices
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Gas valve, two-stage | 0151M00027 | All 22 models | 1 | |
| Burner orifice | 10716005 | All 22 models | 3 | #45 drill |
| Gas manifold | 0120F00007 | GMVC80603BNBC, GMVC80603BNBD, GMVC80603BXBC, GMVC80603BXBD, GMVC80604BNBD, GMVC80604BXBD | 1 | |
| Gas manifold | 0120F00008 | 14 models: GMVC80803BNBC, GMVC80803BNBD, GMVC80803BXBC, GMVC80803BXBD, GMVC80804CNBC, GMVC80804CNBD, GMVC80804CXBC, GMVC80804CXBD, GMVC80805CNBD, GMVC80805CXBD, GMVC80805DNBC, GMVC80805DNBD, GMVC80805DXBC, GMVC80805DXBD | 1 | |
| Gas manifold | 0120F00009 | GMVC81005CNBD, GMVC81005CXBD | 1 | |
| Orifice plate, 3 burner | 4028001 | GMVC80603BNBC, GMVC80603BNBD, GMVC80604BNBD | 1 | |
| Orifice plate, 4 burner | 4028002 | 17 models: GMVC80603BXBC, GMVC80603BXBD, GMVC80604BXBD, GMVC80803BNBC, GMVC80803BNBD, GMVC80803BXBC, GMVC80803BXBD, GMVC80804CNBC, GMVC80804CNBD, GMVC80804CXBC, GMVC80804CXBD, GMVC80805CNBD, GMVC80805CXBD, GMVC80805DNBC, GMVC80805DNBD, GMVC80805DXBC, GMVC80805DXBD | 1 | |
| Orifice plate, 5 burner | 4028003 | GMVC81005CNBD, GMVC81005CXBD | 1 |
Pressure & limit switches
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Inducer pressure switch, single stage | 0130F00049 | GMVC80604BNBD, GMVC80604BXBD, GMVC80805CNBD, GMVC80805CXBD | 1 | |
| Inducer pressure switch, two-stage | 0130F00569 | GMVC80803BNBC, GMVC80803BNBD, GMVC80803BXBC, GMVC80803BXBD | 1 | |
| Inducer pressure switch, two-stage | 0130F00570 | GMVC80804CNBC, GMVC80804CNBD, GMVC80804CXBC, GMVC80804CXBD | 1 | |
| Inducer pressure switch, two-stage | 0130F00571 | 8 models: GMVC80603BNBC, GMVC80603BNBD, GMVC80603BXBC, GMVC80603BXBD, GMVC80805DNBC, GMVC80805DNBD, GMVC80805DXBC, GMVC80805DXBD | 1 | |
| Primary limit switch (blue) | 20162903 | GMVC80603BNBC, GMVC80603BNBD, GMVC80603BXBC, GMVC80603BXBD | 1 | |
| Primary limit switch Goodman service bulletin SF-054 applies to this part | 20162904 | 12 models: GMVC80803BNBC, GMVC80803BNBD, GMVC80803BXBC, GMVC80803BXBD, GMVC80804CNBC, GMVC80804CNBD, GMVC80804CXBC, GMVC80804CXBD, GMVC80805DNBC, GMVC80805DNBD, GMVC80805DXBC, GMVC80805DXBD | 1 | |
| Primary limit switch (yellow) | 20162905 | GMVC81005CNBD, GMVC81005CXBD | 1 | |
| Primary limit switch (gold) | 0130M00063 | GMVC80604BNBD, GMVC80604BXBD, GMVC80805CNBD, GMVC80805CXBD | 1 | 140 °F |
| Blower compartment limit (light blue) | 0130F00038 | All 22 models | 1 | 120 °F |
| Flame rollout switch, manual reset | 10123529 | All 22 models | 2 |
Electrical
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Transformer | 0130M00140 | All 22 models | 1 | 120 V to 24 V, 40 VA |
| Line inductor (choke) for blower motor | 0130M00141 | 10 models: GMVC80604BNBD, GMVC80604BXBD, GMVC80805CNBD, GMVC80805CXBD, GMVC80805DNBC, GMVC80805DNBD, GMVC80805DXBC, GMVC80805DXBD, GMVC81005CNBD, GMVC81005CXBD | 1 | 5.9 A |
| Door interlock switch | 10690402 | All 22 models | 1 | |
| Inducer motor capacitor | DY6.186.070 | All 22 models | 1 | |
| Blower wire harness | 0259F00024 | 8 models: GMVC80804CNBC, GMVC80804CNBD, GMVC80804CXBC, GMVC80804CXBD, GMVC80805DNBC, GMVC80805DNBD, GMVC80805DXBC, GMVC80805DXBD | 1 | |
| Blower power harness | 0259F00049 | All 22 models | 1 | |
| Wire harness | 0259M00008 | All 22 models | 1 | |
| Adapter harness | 0259M00005 | All 22 models | 1 | |
| Inducer harness | 0259F00062 | All 22 models | 1 | |
| Wire harness | 0259F00063 | All 22 models | 1 | |
| Wire harness | 0259F00081 | 8 models: GMVC80603BNBC, GMVC80603BXBC, GMVC80803BNBC, GMVC80803BXBC, GMVC80804CNBC, GMVC80804CXBC, GMVC80805DNBC, GMVC80805DXBC | 1 | |
| Wire harness | 0259F00276 | 14 models: GMVC80603BNBD, GMVC80603BXBD, GMVC80604BNBD, GMVC80604BXBD, GMVC80803BNBD, GMVC80803BXBD, GMVC80804CNBD, GMVC80804CXBD, GMVC80805CNBD, GMVC80805CXBD, GMVC80805DNBD, GMVC80805DXBD, GMVC81005CNBD, GMVC81005CXBD | 1 |
Motors & blowers
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Blower motor, ECM | 0131M00270 | 12 models: GMVC80603BNBC, GMVC80603BNBD, GMVC80603BXBC, GMVC80603BXBD, GMVC80803BNBC, GMVC80803BNBD, GMVC80803BXBC, GMVC80803BXBD, GMVC80804CNBC, GMVC80804CNBD, GMVC80804CXBC, GMVC80804CXBD | 1 | 1/2 HP |
| Blower motor, ECM | 0131M00271 | 10 models: GMVC80604BNBD, GMVC80604BXBD, GMVC80805CNBD, GMVC80805CXBD, GMVC80805DNBC, GMVC80805DNBD, GMVC80805DXBC, GMVC80805DXBD, GMVC81005CNBD, GMVC81005CXBD | 1 | 3/4 HP |
| Blower wheel | 0150M00043 | 8 models: GMVC80603BNBC, GMVC80603BNBD, GMVC80603BXBC, GMVC80603BXBD, GMVC80803BNBC, GMVC80803BNBD, GMVC80803BXBC, GMVC80803BXBD | 1 | 10 x 8 in. |
| Blower wheel | B1368016 | GMVC80604BNBD, GMVC80604BXBD | 1 | 10 x 8 in. |
| Blower wheel | B1368047 | GMVC80805CNBD, GMVC80805CXBD, GMVC81005CNBD, GMVC81005CXBD | 1 | 10 x 10 in. |
| Blower housing with wheel | 0271F00303 | 8 models: GMVC80804CNBC, GMVC80804CNBD, GMVC80804CXBC, GMVC80804CXBD, GMVC80805DNBC, GMVC80805DNBD, GMVC80805DXBC, GMVC80805DXBD | 1 | |
| Blower housing | 0271F00111 | 10 models: GMVC80603BNBC, GMVC80603BNBD, GMVC80603BXBC, GMVC80603BXBD, GMVC80604BNBD, GMVC80604BXBD, GMVC80803BNBC, GMVC80803BNBD, GMVC80803BXBC, GMVC80803BXBD | 1 | |
| Blower housing | 0271F00112 | GMVC80805CNBD, GMVC80805CXBD, GMVC81005CNBD, GMVC81005CXBD | 1 | |
| Blower motor mount band | 0121M00038 | 10 models: GMVC80603BNBC, GMVC80603BNBD, GMVC80603BXBC, GMVC80603BXBD, GMVC80604BNBD, GMVC80604BXBD, GMVC80803BNBC, GMVC80803BNBD, GMVC80803BXBC, GMVC80803BXBD | 1 | |
| Blower motor mount band, heavy duty | 0121M00039 | 12 models: GMVC80804CNBC, GMVC80804CNBD, GMVC80804CXBC, GMVC80804CXBD, GMVC80805CNBD, GMVC80805CXBD, GMVC80805DNBC, GMVC80805DNBD, GMVC80805DXBC, GMVC80805DXBD, GMVC81005CNBD, GMVC81005CXBD | 1 | |
| Blower motor mount arm | B1376853 | 10 models: GMVC80603BNBC, GMVC80603BNBD, GMVC80603BXBC, GMVC80603BXBD, GMVC80604BNBD, GMVC80604BXBD, GMVC80803BNBC, GMVC80803BNBD, GMVC80803BXBC, GMVC80803BXBD | 1 | |
| Blower motor mount arm, heavy duty | B1376863 | 12 models: GMVC80804CNBC, GMVC80804CNBD, GMVC80804CXBC, GMVC80804CXBD, GMVC80805CNBD, GMVC80805CXBD, GMVC80805DNBC, GMVC80805DNBD, GMVC80805DXBC, GMVC80805DXBD, GMVC81005CNBD, GMVC81005CXBD | 1 | |
| Blower cut-off plate | 764740 | 10 models: GMVC80603BNBC, GMVC80603BNBD, GMVC80603BXBC, GMVC80603BXBD, GMVC80604BNBD, GMVC80604BXBD, GMVC80803BNBC, GMVC80803BNBD, GMVC80803BXBC, GMVC80803BXBD | 1 | 10 x 8 in. |
| Blower cut-off plate | 764741 | GMVC80805CNBD, GMVC80805CXBD, GMVC81005CNBD, GMVC81005CXBD | 1 | 10 x 10 in. |
Inducer & venting
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Inducer (draft) motor, two-stage | 0131M00781P | All 22 models | 1 | |
| Flue collector box | 0121F00328 | GMVC80603BNBC, GMVC80603BNBD, GMVC80603BXBC, GMVC80603BXBD | 1 | 17.5 in., 1.250 in. outlet |
| Flue collector box | 0121F00332 | GMVC80604BNBD, GMVC80604BXBD | 1 | 17.5 in., 1.375 in. outlet |
| Flue collector box | 0121F00655 | GMVC80803BNBC, GMVC80803BNBD, GMVC80803BXBC, GMVC80803BXBD | 1 | 17.5 in., 1.437 in. outlet |
| Flue collector box | 0121F00659 | GMVC80804CNBC, GMVC80804CNBD, GMVC80804CXBC, GMVC80804CXBD | 1 | 21 in., 1.40 in. outlet |
| Flue collector box | 0121F00336 | GMVC80805CNBD, GMVC80805CXBD | 1 | 21 in., 1.50 in. outlet |
| Flue collector box | 0121F00334 | GMVC80805DNBC, GMVC80805DNBD, GMVC80805DXBC, GMVC80805DXBD | 1 | 1.625 in. outlet |
| Flue collector box | 0121F00333 | GMVC81005CNBD, GMVC81005CXBD | 1 | 21 in., 1.75 in. outlet |
| Collector box gasket | 0154F00004 | 10 models: GMVC80603BNBC, GMVC80603BNBD, GMVC80603BXBC, GMVC80603BXBD, GMVC80604BNBD, GMVC80604BXBD, GMVC80803BNBC, GMVC80803BNBD, GMVC80803BXBC, GMVC80803BXBD | 1 | 17.5 in. |
| Collector box gasket | 0154F00005 | 12 models: GMVC80804CNBC, GMVC80804CNBD, GMVC80804CXBC, GMVC80804CXBD, GMVC80805CNBD, GMVC80805CXBD, GMVC80805DNBC, GMVC80805DNBD, GMVC80805DXBC, GMVC80805DXBD, GMVC81005CNBD, GMVC81005CXBD | 1 | 21 in. |
| Chimney transition, bottom | 0128F00006 | All 22 models | 1 | |
| Chimney transition, top | 4023500 | All 22 models | 1 |
Heat exchanger & burners
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Heat exchanger assembly | 0270F00929 | GMVC80603BNBC, GMVC80603BNBD, GMVC80603BXBC, GMVC80603BXBD, GMVC80604BNBD, GMVC80604BXBD | 1 | |
| Heat exchanger assembly | 0270F00902 | GMVC80803BNBC, GMVC80803BNBD, GMVC80803BXBC, GMVC80803BXBD | 1 | |
| Heat exchanger assembly | 0270F00930 | GMVC80804CNBC, GMVC80804CNBD, GMVC80804CXBC, GMVC80804CXBD, GMVC80805CNBD, GMVC80805CXBD | 1 | |
| Heat exchanger assembly | 0270F02961 | GMVC80805DNBC, GMVC80805DNBD, GMVC80805DXBC, GMVC80805DXBD | 1 | |
| Heat exchanger assembly | 0270F00903 | GMVC81005CNBD, GMVC81005CXBD | 1 | |
| Inshot burner, 3 in. | B4022700 | All 22 models | 3 | |
| Burner rack, 3 burner | 0121F00168 | GMVC80603BNBC, GMVC80603BNBD, GMVC80603BXBC, GMVC80603BXBD, GMVC80604BNBD, GMVC80604BXBD | 1 | |
| Burner rack, 4 burner | 0121F00169 | 14 models: GMVC80803BNBC, GMVC80803BNBD, GMVC80803BXBC, GMVC80803BXBD, GMVC80804CNBC, GMVC80804CNBD, GMVC80804CXBC, GMVC80804CXBD, GMVC80805CNBD, GMVC80805CXBD, GMVC80805DNBC, GMVC80805DNBD, GMVC80805DXBC, GMVC80805DXBD | 1 | |
| Burner rack, 5 burner | 0121F00170 | GMVC81005CNBD, GMVC81005CXBD | 1 | |
| Burner box top, 3 burner | 0121F00163 | GMVC80603BNBC, GMVC80603BNBD, GMVC80603BXBC, GMVC80603BXBD, GMVC80604BNBD, GMVC80604BXBD | 1 | |
| Burner box top, 4 burner | 0121F00164 | 14 models: GMVC80803BNBC, GMVC80803BNBD, GMVC80803BXBC, GMVC80803BXBD, GMVC80804CNBC, GMVC80804CNBD, GMVC80804CXBC, GMVC80804CXBD, GMVC80805CNBD, GMVC80805CXBD, GMVC80805DNBC, GMVC80805DNBD, GMVC80805DXBC, GMVC80805DXBD | 1 | |
| Burner box top, 5 burner | 0121F00165 | GMVC81005CNBD, GMVC81005CXBD | 1 | |
| Burner box side | 0121F00146 | All 22 models | 2 |
Cabinet & doors
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Blower door, painted | 0121F00123DG | 10 models: GMVC80603BNBC, GMVC80603BNBD, GMVC80603BXBC, GMVC80603BXBD, GMVC80604BNBD, GMVC80604BXBD, GMVC80803BNBC, GMVC80803BNBD, GMVC80803BXBC, GMVC80803BXBD | 1 | 17.5 in. cabinet |
| Blower door, painted | 0121F00124DG | 8 models: GMVC80804CNBC, GMVC80804CNBD, GMVC80804CXBC, GMVC80804CXBD, GMVC80805CNBD, GMVC80805CXBD, GMVC81005CNBD, GMVC81005CXBD | 1 | 21 in. cabinet |
| Blower door, painted | 0121F00125DG | GMVC80805DNBC, GMVC80805DNBD, GMVC80805DXBC, GMVC80805DXBD | 1 | 24.5 in. cabinet |
| Control access door, painted | 0121F00119DG | 10 models: GMVC80603BNBC, GMVC80603BNBD, GMVC80603BXBC, GMVC80603BXBD, GMVC80604BNBD, GMVC80604BXBD, GMVC80803BNBC, GMVC80803BNBD, GMVC80803BXBC, GMVC80803BXBD | 1 | 17.5 in. cabinet |
| Control access door, painted | 0121F00120DG | 8 models: GMVC80804CNBC, GMVC80804CNBD, GMVC80804CXBC, GMVC80804CXBD, GMVC80805CNBD, GMVC80805CXBD, GMVC81005CNBD, GMVC81005CXBD | 1 | 21 in. cabinet |
| Control access door, painted | 0121F00121DG | GMVC80805DNBC, GMVC80805DNBD, GMVC80805DXBC, GMVC80805DXBD | 1 | 24.5 in. cabinet |
| Furnace top, painted | 0121F00142DG | 10 models: GMVC80603BNBC, GMVC80603BNBD, GMVC80603BXBC, GMVC80603BXBD, GMVC80604BNBD, GMVC80604BXBD, GMVC80803BNBC, GMVC80803BNBD, GMVC80803BXBC, GMVC80803BXBD | 1 | 17.5 in. cabinet |
| Furnace top, painted | 0121F00143DG | 8 models: GMVC80804CNBC, GMVC80804CNBD, GMVC80804CXBC, GMVC80804CXBD, GMVC80805CNBD, GMVC80805CXBD, GMVC81005CNBD, GMVC81005CXBD | 1 | 21 in. cabinet |
| Furnace top, painted | 0121F00463DG | GMVC80805DNBC, GMVC80805DNBD, GMVC80805DXBC, GMVC80805DXBD | 1 | 24.5 in. cabinet |
| Control mounting panel | 0121F00218 | All 22 models | 1 | |
| Blower door view port bushing | B1392139 | All 22 models | 1 | |
| Universal bushing | B1392147 | All 22 models | 1 | |
| Junction box | 4014502 | All 22 models | 1 | |
| Junction box cover | 4015502 | All 22 models | 1 | |
| Nameplate | 0161F00007 | All 22 models | 1 |
Other
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Flat washer | B1392918 | All 22 models | 3 | 1/4 in. ID x 1 in. OD |
| Hex head tap bolt | 0163M00320 | All 22 models | 1 | |
| Screw | M0250565 | All 22 models | 3 | 1.25 in. |
| Locknut, nylon insert | B1393800 | All 22 models | 1 | 1/4-20 |
Source: Goodman repair parts manual RP-G2301A (July 2018) (pages 3, 5, 7, 9). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.