Goodman · Furnace · GMVC8 series

GMVC80603BNBD parts

50 replacement parts that fit the Goodman GMVC80603BNBD, with OEM part numbers, grouped by system.

Controls & boards

PartPart #QtySize / rating
Integrated furnace control boardPCBKF1051
Model data card for control board0130F005331

Ignition & flame

PartPart #QtySize / rating
Hot surface igniter, silicon nitride0130F000081
Flame sensor0130F000101

Gas valve & orifices

PartPart #QtySize / rating
Gas valve, two-stage0151M000271
Burner orifice107160053#45 drill
Gas manifold0120F000071
Orifice plate, 3 burner40280011

Pressure & limit switches

PartPart #QtySize / rating
Inducer pressure switch, two-stage0130F005711
Primary limit switch (blue)201629031
Blower compartment limit (light blue)0130F000381120 °F
Flame rollout switch, manual reset101235292

Electrical

PartPart #QtySize / rating
Transformer0130M001401120 V to 24 V, 40 VA
Door interlock switch106904021
Inducer motor capacitorDY6.186.0701
Blower power harness0259F000491
Wire harness0259M000081
Adapter harness0259M000051
Inducer harness0259F000621
Wire harness0259F000631
Wire harness0259F002761

Motors & blowers

PartPart #QtySize / rating
Blower motor, ECM0131M0027011/2 HP
Blower wheel0150M00043110 x 8 in.
Blower housing0271F001111
Blower motor mount band0121M000381
Blower motor mount armB13768531
Blower cut-off plate764740110 x 8 in.

Inducer & venting

PartPart #QtySize / rating
Inducer (draft) motor, two-stage0131M00781P1
Flue collector box0121F00328117.5 in., 1.250 in. outlet
Collector box gasket0154F00004117.5 in.
Chimney transition, bottom0128F000061
Chimney transition, top40235001

Heat exchanger & burners

PartPart #QtySize / rating
Heat exchanger assembly0270F009291
Inshot burner, 3 in.B40227003
Burner rack, 3 burner0121F001681
Burner box top, 3 burner0121F001631
Burner box side0121F001462

Cabinet & doors

PartPart #QtySize / rating
Blower door, painted0121F00123DG117.5 in. cabinet
Control access door, painted0121F00119DG117.5 in. cabinet
Furnace top, painted0121F00142DG117.5 in. cabinet
Control mounting panel0121F002181
Blower door view port bushingB13921391
Universal bushingB13921471
Junction box40145021
Junction box cover40155021
Nameplate0161F000071

Other

PartPart #QtySize / rating
Flat washerB139291831/4 in. ID x 1 in. OD
Hex head tap bolt0163M003201
ScrewM025056531.25 in.
Locknut, nylon insertB139380011/4-20

Source: Goodman repair parts manual RP-G2301A (July 2018) (pages 3, 5, 7, 9). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.