Glow Brand · Boiler · B85/B120/B160 series

B85 parts

96 replacement parts that fit the Glow Brand B85, with OEM part numbers, grouped by system.

Controls & boards

PartPart #QtySize / rating
Flue temperature sensorGLO-421
Display board decalCB-1191
Display board enclosureCB-1231
Display boardCB-1221
Ignition control board (ICB) with 5 A fuse
Fuse is a B-221 5 A 250 V
B-2211
Display board enclosure screwsCB-1821
Temperature sensor clip (supply/return)GLO-411

Ignition & flame

PartPart #QtySize / rating
Ionization electrode cable (585 mm)GLO-441
Ignition electrode cable (1095 mm)CB-1091
Ignition electrode gasketGLO-5861
Ignition electrodeGLO-582-11
Electrode mounting screwsGLO-5881
Ionization electrodeGLO-5831
Ionization electrode gasketGLO-5871

Gas valve & orifices

PartPart #QtySize / rating
Brass fitting 3/4 in. NPTGLO-180-501
Fibre washer 3/4 in., gas pipeGLO-1721
Gas supply tubeCB-1031
Fibre washer 1/2 in., gas pipeGLO-1731
Gas valve screw M4 x 12 hexGLO-5631
Gas valve cork gasketGLO-1701
Brass boiler gas valve fittingCB-1301
Gas valveGLO-5411
Gas valve rubber coupling (valve to venturi)GLO-5471
Gas valve mounting screws (T25)GLO-180-1102
Venturi 20 mm (B85)CB-1831

Pressure & limit switches

PartPart #QtySize / rating
Blocked flue switchGLO-180-1501
Hose barb 3/16 in. nylonGLO-511
Blocked flue switch mounting bracketGLO-180-211
High limit switch screwGLO-180-1001
High limit switch 95 C (203 F)EKA-323-391
Water pressure sensorB-1501
Barbed tee 3/16 in. (flue switch loop)GLO-651

Electrical

PartPart #QtySize / rating
Terminal strip screwCB-1371
Control terminal stripCB-1161
Field wiring strip bracketB-194-S1
Field wiring terminal strip labelB-2401
Silicone cable grommetCB-1271
LWCO jumper (factory installed)LWCO JUMPER1

Motors & blowers

PartPart #QtySize / rating
Combustion fanGLO-5431
Fan to venturi O-ringGLO-5441
Venturi mounting hex screw (T30)GLO-180-1093

Inducer & venting

PartPart #QtySize / rating
Galvanized vent screenSCREEN2
PVC vent plugGLO-02-PLUG1
PVC combustion air inlet adapterGLO-011
CPVC exhaust flue adapterGLO-031
Vent adapter screwGLO-180-1148
Flue outlet adapter 60 mmGLO-621

Heat exchanger & burners

PartPart #QtySize / rating
Heat exchanger assembly, Isothermic ASME H (B85)CB-1121
Heat exchanger holding clampGLO-601
Fan/burner gasketGLO-501
Heat exchanger support clamps (B85, 2 pcs)CB-1142
Stainless heat exchanger clipGLO-701
Stainless steel heat exchanger (B85)CB-1501
Heat exchanger refractory insulation (rear)GLO-180-751
Cork gasket, heat exchangerCB-1591
Burner plate gasketGLO-5851
Burner plate refractory insulationGLO-180-741
Burner and plate (B85)
Printed as C85 in the list; fits B85
CB-1521
Burner mounting nutsGLO-5894

Condensate

PartPart #QtySize / rating
Condensate hose connector 3/4 to 1/2 in.GLO-180-2001
Plastic condensate fitting 1/2 to 1/2 in.GLO-180-771
Heat exchanger condensate tubeGLO-180-1111
Gear clampGLO-180-411
Condensate trapGLO-481
Condensate drain tubeGLO-471
Condensate hose grommetGRO-0011
Silicone condensate hoseGLO-180-221

Water / hydronic

PartPart #QtySize / rating
Automatic air vent, high capacity 150 psiCB-1111
Air vent grommetCB-1261
Air vent fittingCB-1311
O-ring, auto air ventCB-1611
Air vent clipCB-2501
O-ringCB-1491
CH supply copper tubeB-1111
Rubber washer 3/4 in.GLO-401
Pressure gauge fixtureB-1171
Safety relief valve 30 psiCB-1361
CH return copper tubeB-1101
Manual air ventCB-1561

Cabinet & doors

PartPart #QtySize / rating
Screw 8-32 x 3/8 pan Phillips type FGLO-180-1031
Screw 10-32 x 1/2 panGLO-180-1071
Hinge, doorCB-193-S1
Lock nut 10-32GLO-180-1081
Screw 10-32 x 1/2GLO-180-1051
Hex screw M5 x 12 DIN933GLO-180-1061
Thread cutting screw 10-24 x 1/2 HWHGLO-180-1041
Front door mounting bracketGLO-180-S-091
Left panel, painted (B85)CB-202-S1
Right panel, painted (B85)CB-201-S1
Wrap rear support mounting bracketCB-192-S1
Boiler wrap, unpainted (B85)B-190-S1
Wall mount support bracketGLO-180-S-131
Front door, paintedCB-200-S1

Other

PartPart #QtySize / rating
Wire harness clipGLO-671
Zip tiesCB-1151
Cotter pin 1/8 x 3-1/2 in.CB-1481

Same series

The B85/B120/B160 parts list shows every part for all 3 models side by side. Other models: B120, B160.

Source: Glow Brand B85/B120/B160 Installation & Operation Manual V20231025 (15.1 Part List). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.