Parts / Glow Brand / B85/B120/B160 / B120
Glow Brand · Boiler · B85/B120/B160 series
B120 parts
96 replacement parts that fit the Glow Brand B120, with OEM part numbers, grouped by system.
Controls & boards Part Part # Qty Size / rating Flue temperature sensor GLO-42 1 Display board decal CB-119 1 Display board enclosure CB-123 1 Display board CB-122 1 Ignition control board (ICB) with 5 A fuseFuse is a B-221 5 A 250 V B-221 1 Display board enclosure screws CB-182 1 Temperature sensor clip (supply/return) GLO-41 1
Ignition & flame Part Part # Qty Size / rating Ionization electrode cable (585 mm) GLO-44 1 Ignition electrode cable (1095 mm) CB-109 1 Ignition electrode gasket GLO-586 1 Ignition electrode GLO-582-1 1 Electrode mounting screws GLO-588 1 Ionization electrode GLO-583 1 Ionization electrode gasket GLO-587 1
Gas valve & orifices Part Part # Qty Size / rating Brass fitting 3/4 in. NPT GLO-180-50 1 Fibre washer 3/4 in., gas pipe GLO-172 1 Gas supply tube CB-103 1 Fibre washer 1/2 in., gas pipe GLO-173 1 Gas valve screw M4 x 12 hex GLO-563 1 Gas valve cork gasket GLO-170 1 Brass boiler gas valve fitting CB-130 1 Gas valve GLO-541 1 Gas valve rubber coupling (valve to venturi) GLO-547 1 Gas valve mounting screws (T25) GLO-180-110 2 Venturi 24 mm (B120/B160) CB-184 1
Pressure & limit switches Electrical Part Part # Qty Size / rating Terminal strip screw CB-137 1 Control terminal strip CB-116 1 Field wiring strip bracket B-194-S 1 Field wiring terminal strip label B-240 1 Silicone cable grommet CB-127 1 LWCO jumper (factory installed) LWCO JUMPER 1
Motors & blowers Inducer & venting Heat exchanger & burners Part Part # Qty Size / rating Heat exchanger assembly, Isothermic ASME H (B120/B160) CB-113 1 Heat exchanger holding clamp GLO-60 1 Fan/burner gasket GLO-50 1 Heat exchanger support clamps (B120/B160, 2 pcs) GLO-59 2 Stainless heat exchanger clip GLO-70 1 Stainless steel heat exchanger (B120/B160) CB-151 1 Heat exchanger refractory insulation (rear) GLO-180-75 1 Cork gasket, heat exchanger CB-159 1 Burner plate gasket GLO-585 1 Burner plate refractory insulation GLO-180-74 1 Burner and plate (B120/B160)Printed as C120 in the list; B120/B160 CB-153 1 Burner mounting nuts GLO-589 4
Condensate Water / hydronic Part Part # Qty Size / rating Automatic air vent, high capacity 150 psi CB-111 1 Air vent grommet CB-126 1 Air vent fitting CB-131 1 O-ring, auto air vent CB-161 1 Air vent clip CB-250 1 O-ring CB-149 1 CH supply copper tube B-111 1 Rubber washer 3/4 in. GLO-40 1 Pressure gauge fixture B-117 1 Safety relief valve 30 psi CB-136 1 CH return copper tube B-110 1 Manual air vent CB-156 1
Cabinet & doors Other Part Part # Qty Size / rating Wire harness clip GLO-67 1 Zip ties CB-115 1 Cotter pin 1/8 x 3-1/2 in. CB-148 1
Source: Glow Brand B85/B120/B160 Installation & Operation Manual V20231025 (15.1 Part List). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.