Glow Brand · Boiler parts

Glow Brand B85, B120 and B160 condensing boiler: parts list

104 replacement parts with OEM part numbers for 3 models. Pick your model for a list of only the parts that fit it.

Jump to: Controls & boards · Ignition & flame · Gas valve & orifices · Pressure & limit switches · Electrical · Motors & blowers · Inducer & venting · Heat exchanger & burners · Condensate · Water / hydronic · Cabinet & doors · Other

Controls & boards

PartPart #FitsQtySize / rating
Flue temperature sensorGLO-42All 3 models1
Display board decalCB-119All 3 models1
Display board enclosureCB-123All 3 models1
Display boardCB-122All 3 models1
Ignition control board (ICB) with 5 A fuse
Fuse is a B-221 5 A 250 V
B-221All 3 models1
Display board enclosure screwsCB-182All 3 models1
Temperature sensor clip (supply/return)GLO-41All 3 models1

Ignition & flame

PartPart #FitsQtySize / rating
Ionization electrode cable (585 mm)GLO-44All 3 models1
Ignition electrode cable (1095 mm)CB-109All 3 models1
Ignition electrode gasketGLO-586All 3 models1
Ignition electrodeGLO-582-1All 3 models1
Electrode mounting screwsGLO-588All 3 models1
Ionization electrodeGLO-583All 3 models1
Ionization electrode gasketGLO-587All 3 models1

Gas valve & orifices

PartPart #FitsQtySize / rating
Brass fitting 3/4 in. NPTGLO-180-50All 3 models1
Fibre washer 3/4 in., gas pipeGLO-172All 3 models1
Gas supply tubeCB-103All 3 models1
Fibre washer 1/2 in., gas pipeGLO-173All 3 models1
Gas valve screw M4 x 12 hexGLO-563All 3 models1
Gas valve cork gasketGLO-170All 3 models1
Brass boiler gas valve fittingCB-130All 3 models1
Gas valveGLO-541All 3 models1
Gas valve rubber coupling (valve to venturi)GLO-547All 3 models1
Gas valve mounting screws (T25)GLO-180-110All 3 models2
Venturi 20 mm (B85)CB-183B851
Venturi 24 mm (B120/B160)CB-184B120, B1601

Pressure & limit switches

PartPart #FitsQtySize / rating
Blocked flue switchGLO-180-150All 3 models1
Hose barb 3/16 in. nylonGLO-51All 3 models1
Blocked flue switch mounting bracketGLO-180-21All 3 models1
High limit switch screwGLO-180-100All 3 models1
High limit switch 95 C (203 F)EKA-323-39All 3 models1
Water pressure sensorB-150All 3 models1
Barbed tee 3/16 in. (flue switch loop)GLO-65All 3 models1

Electrical

PartPart #FitsQtySize / rating
Terminal strip screwCB-137All 3 models1
Control terminal stripCB-116All 3 models1
Field wiring strip bracketB-194-SAll 3 models1
Field wiring terminal strip labelB-240All 3 models1
Silicone cable grommetCB-127All 3 models1
LWCO jumper (factory installed)LWCO JUMPERAll 3 models1

Motors & blowers

PartPart #FitsQtySize / rating
Combustion fanGLO-543All 3 models1
Fan to venturi O-ringGLO-544All 3 models1
Venturi mounting hex screw (T30)GLO-180-109All 3 models3

Inducer & venting

PartPart #FitsQtySize / rating
Galvanized vent screenSCREENAll 3 models2
PVC vent plugGLO-02-PLUGAll 3 models1
PVC combustion air inlet adapterGLO-01All 3 models1
CPVC exhaust flue adapterGLO-03All 3 models1
Vent adapter screwGLO-180-114All 3 models8
Flue outlet adapter 60 mmGLO-62All 3 models1

Heat exchanger & burners

PartPart #FitsQtySize / rating
Heat exchanger assembly, Isothermic ASME H (B85)CB-112B851
Heat exchanger assembly, Isothermic ASME H (B120/B160)CB-113B120, B1601
Heat exchanger holding clampGLO-60All 3 models1
Fan/burner gasketGLO-50All 3 models1
Heat exchanger support clamps (B85, 2 pcs)CB-114B852
Heat exchanger support clamps (B120/B160, 2 pcs)GLO-59B120, B1602
Stainless heat exchanger clipGLO-70All 3 models1
Stainless steel heat exchanger (B85)CB-150B851
Stainless steel heat exchanger (B120/B160)CB-151B120, B1601
Heat exchanger refractory insulation (rear)GLO-180-75All 3 models1
Cork gasket, heat exchangerCB-159All 3 models1
Burner plate gasketGLO-585All 3 models1
Burner plate refractory insulationGLO-180-74All 3 models1
Burner and plate (B85)
Printed as C85 in the list; fits B85
CB-152B851
Burner and plate (B120/B160)
Printed as C120 in the list; B120/B160
CB-153B120, B1601
Burner mounting nutsGLO-589All 3 models4

Condensate

PartPart #FitsQtySize / rating
Condensate hose connector 3/4 to 1/2 in.GLO-180-200All 3 models1
Plastic condensate fitting 1/2 to 1/2 in.GLO-180-77All 3 models1
Heat exchanger condensate tubeGLO-180-111All 3 models1
Gear clampGLO-180-41All 3 models1
Condensate trapGLO-48All 3 models1
Condensate drain tubeGLO-47All 3 models1
Condensate hose grommetGRO-001All 3 models1
Silicone condensate hoseGLO-180-22All 3 models1

Water / hydronic

PartPart #FitsQtySize / rating
Automatic air vent, high capacity 150 psiCB-111All 3 models1
Air vent grommetCB-126All 3 models1
Air vent fittingCB-131All 3 models1
O-ring, auto air ventCB-161All 3 models1
Air vent clipCB-250All 3 models1
O-ringCB-149All 3 models1
CH supply copper tubeB-111All 3 models1
Rubber washer 3/4 in.GLO-40All 3 models1
Pressure gauge fixtureB-117All 3 models1
Safety relief valve 30 psiCB-136All 3 models1
CH return copper tubeB-110All 3 models1
Manual air ventCB-156All 3 models1

Cabinet & doors

PartPart #FitsQtySize / rating
Screw 8-32 x 3/8 pan Phillips type FGLO-180-103All 3 models1
Screw 10-32 x 1/2 panGLO-180-107All 3 models1
Hinge, doorCB-193-SAll 3 models1
Lock nut 10-32GLO-180-108All 3 models1
Screw 10-32 x 1/2GLO-180-105All 3 models1
Hex screw M5 x 12 DIN933GLO-180-106All 3 models1
Thread cutting screw 10-24 x 1/2 HWHGLO-180-104All 3 models1
Front door mounting bracketGLO-180-S-09All 3 models1
Left panel, painted (B85)CB-202-SB851
Left panel, painted (B120/B160)CB-203-SB120, B1601
Right panel, painted (B85)CB-201-SB851
Right panel, painted (B120/B160)CB-204-SB120, B1601
Wrap rear support mounting bracketCB-192-SAll 3 models1
Boiler wrap, unpainted (B85)B-190-SB851
Boiler wrap, unpainted (B120/B160)B-191-SB120, B1601
Wall mount support bracketGLO-180-S-13All 3 models1
Front door, paintedCB-200-SAll 3 models1

Other

PartPart #FitsQtySize / rating
Wire harness clipGLO-67All 3 models1
Zip tiesCB-115All 3 models1
Cotter pin 1/8 x 3-1/2 in.CB-148All 3 models1

Source: Glow Brand B85/B120/B160 Installation & Operation Manual V20231025 (15.1 Part List). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.