Noritz · Tankless water heater troubleshooting
Draining to prevent freezing - Noritz EZ/NRCR
What is going on
Drain the heater when it will be unpowered or unused in freezing conditions. The unit must stay plugged in for freeze protection.
Likely causes
- Power loss in cold weather
- Vacant home
Check in this order
- Warning: Turn the heater off and let it cool first.
- Using the display power button off > menu > Drain Water > Start (or app: User Setting > Drain Water on).
- Close the water supply valve and open all hot fixtures.
- EZ open all drain plugs. NRCR: open drain plug A (hot side), drain plug with filter B (cold side), then C, D and E, or use the isolation valve ports.
- Manual draining without power close gas, run hot water over 2 minutes per unit; code 11 or 41 may show and is not a fault.
- Refit all plugs; if unpowered, blow remaining water out with an air compressor.
- Danger: when restarting, the condensate trap must refill - run the unit and confirm condensate drains within about 15 minutes.
Applies to: Noritz EZ111/EZ98/EZ71 and NRCR111/NRCR92
More tankless water heater guides
- Cleaning ignition and flame rods - Noritz
- Cleaning the fan and burner - Noritz EZ/NRCR/CDV
- Descaling (flushing) the heat exchanger - Noritz
- Field gas conversion NG to LP - Noritz NRCR/EZ Pro
- Heat exchanger replacement - Noritz NRC111 / NCC199
- Heater does not fire when hot water is opened - Noritz tankless
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Noritz EZ/NRCR Owner's Guide (Rev. 10-25), Preventing damage from freezing, p.24-25. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.