Trane · General troubleshooting
Thermostat placement
What is going on
Place the thermostat where it senses room temperature correctly and is not affected by heat or airflow sources.
Check in this order
- Mount on an interior wall, in a central location with good air circulation.
- Keep it away from lamps, sunlight, fireplaces and other radiant heat.
- Keep it away from windows, doors to the outside, outside walls, and alcoves with poor air flow.
- Keep it out of direct air from supply registers or ceiling fans.
- Do not mount it on a wall that has hot or cold water pipes or ductwork.
- Mount it about 5 feet from the ceiling fan area as shown in Figure 1 to avoid trapped heat.
Applies to: XR202 wall mounting in climate-controlled spaces
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Trane XR202 installation and user guide (18-HD51D1-1C-EN), p. 4. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.