Trane · General troubleshooting

Mounting the XR203 to the wall

XR203

What is going on

Mount the sub-base, wire it, then snap the thermostat body on. Do not pry the thermostat off the base.

Check in this order

  1. Turn off all power to the heating and cooling equipment.
  2. If replacing a thermostat, record the color and terminal marking of each wire, disconnect them and remove the old unit.
  3. Pull the thermostat body off the base carefully. Do not force or pry it.
  4. Mark the mounting holes using the base as a template, then move the base aside.
  5. Drill mounting holes. Pull the wire bundle through the base opening and secure the sub-base.
  6. Connect wires to the terminal block using the correct wiring diagram.
  7. Push excess wire into the wall and plug the hole with fire-resistant material such as fiberglass insulation to prevent drafts.
  8. Remove the battery tag to engage the batteries and reattach the thermostat body.

Applies to: XR203 sub-base installation

More general guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Trane XR203 Installation and User Guide 18-HD50D1-1D-EN, p. 4. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.