Trane · General troubleshooting
Mounting the XR202 sub-base and wiring
What is going on
Mount the sub-base, wire it to the terminal block and seal the wall opening.
Check in this order
- Turn OFF all power to heating and cooling equipment.
- If replacing a thermostat, record the color and terminal marking of each wire before removing them.
- Pull the thermostat body off the base by hand. Do not force or pry it.
- Mark hole locations using the base as a template, drill, and mount the sub-base level.
- Connect wires to the terminal block using the wiring diagram for the system.
- Push excess wire into the wall and plug the opening with fire-resistant material such as fiberglass insulation to prevent drafts.
- Clip the RC/RH jumper only if the system has separate RC and RH wires.
Applies to: XR202 installation
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Trane XR202 installation and user guide (18-HD51D1-1C-EN), p. 4. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.