Mounting the XR102 thermostat

XR102

What is going on

Standard wall mounting and wiring sequence for the thermostat sub-base.

Check in this order

  1. Turn off all power to the heating and cooling equipment.
  2. If replacing a thermostat, label each wire's color and terminal, disconnect them without letting them drop into the wall, and remove the old unit.
  3. Pull the cover off the body carefully; do not force or pry it.
  4. Hold the body over the wall hole and mark the mounting holes using the base as a template.
  5. Move the base aside and drill the holes. Pull the wire bundle through the base if reusing existing holes, then mount the sub-base. Level it for appearance only.
  6. Connect wires to the base terminal block using the correct wiring diagram for the system.
  7. Push extra wire back into the wall and plug the hole with fire-resistant material such as fiberglass to prevent drafts.
  8. Remove the battery tag to connect the factory batteries.

Applies to: Trane XR102

More general guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Trane XR102 Non-Programmable Thermostat Installation and User Guide, p. 4. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.