Trane · General troubleshooting
Heat, cool or fan runs constantly
What is going on
System runs with no call for heat, cool or fan.
Likely causes
- Short in wiring
- Short in thermostat
- Short in heat/cool/fan system
- FAN switch set to ON
Check in this order
- Check each wire so none are shorted or touching.
- Make sure no bare wire sticks out from the terminal block.
- Reset the thermostat and retest.
- If the fault remains, have the system tested by the manufacturer or service person.
- If the system tests good, replace the thermostat.
Applies to: TCONT302 / TCONT303
More general guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Trane XR302/XR303 installation and user guide, p. 24. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.