Rinnai · Combi boiler troubleshooting

Replacement gas valve assembly comes with a propane orifice

I-Series Plus 175K and higher

What is going on

Service gas control assembly 806000089 for the I-Series Plus 175K and larger ships with the propane (LP) orifice installed. On a natural gas unit the orifice must be swapped before firing.

Likely causes

  • New gas valve assembly installed on a natural gas boiler without changing the orifice

Check in this order

  1. Gas off, power off. Gas work by a licensed gas technician only.
  2. Find the orifice cover plate on top of the gas valve and remove its 3 screws.
  3. Take out the LP orifice (gray) and put in the NG orifice (black) that comes in the box.
  4. Check the gasket the grooved side must face outward. Refit the cover plate with the 3 screws.
  5. Leak test, then check combustion per the boiler manual.
  6. For other Rinnai products the service assembly is 106000117 (RU/CU tankless and the older I-Series boiler): NG orifice blue, LP orifice red.

Applies to: Rinnai I-Series Plus 175K BTU and larger boilers and combi boilers (gas valve assembly 806000089)

More combi boiler guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Rinnai Gas Control Orifice Instructions U334-9053(01) / 800000266, p.1. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.