F.971 Gas fitting replaced, calibration value not entered
What the control is telling you
The burner is in a fault state because the gas fitting was replaced and its CV2 calibration value was not entered.
Applies to: Vitocrossal 200 CI2
Likely causes
- New gas fitting installed without entering the CV2 calibration value
Test and repair steps
- Read the CV2 calibration value from the label on the gas fitting.
- Enter the CV2 calibration value in ViGuide under Spare parts replacement, then Gas fitting.
Models that show this code
21 models in Vitocrossal 200 CI2
Other codes on the same units
- F.896 Safety chain 1 has responded
- F.897 Safety chain 2 has responded
- F.920 MZIO function fault, digital input 1
- F.921 MZIO function fault, digital input 2
- F.922 MZIO function fault, digital input 3
- F.982 No heating or DHW: heating circuit 1 pump running dry
- F.986 Parameter plausibility check failed between burner 1 and burner 2
- F.99 PlusBus communication error
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Vitocrossal 200 CI2 Service Instructions, p. 73. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.